2005Journal of Biomedical OpticsOpen access

Characterizing the thermally induced structural changes to intact porcine eye, part 1: second harmonic generation imaging of cornea stroma

Hsin‐Yuan Tan, Shu‐Wen Teng, Wen Lo, Wei‐Chou Lin, Sung‐Jan Lin, Shiou‐Hwa Jee, Chen‐Yuan Dong

Open full text 47 citations

Abstract

We characterize the structural changes of porcine corneal structures from 25 to 90 degrees C using second harmonic generation (SHG) microscopy. Our results show that porcine stroma undergoes several distinct stages of structural changes between 25 and 90 degrees C. A decrease in SHG intensity from 30 to 45 degrees C and the existence of SHG intensity peaks at 53, 65, and 77 degrees C correlate to distinct structural alterations of the corneal stroma. At higher temperatures, the SHG intensity decreases and a baseline in SHG signal is reached at 90 degrees C. Our results demonstrate that SHG microscopy is a useful technique for obtaining qualitative and quantitative information of thermally treated corneal fibers without histological or labeling procedures. With additional developments, SHG imaging may be developed into an effective imaging technique for in vivo characterization of cornea structural changes.

Open-access reader

About this research paper

What this paper is about

We characterize the structural changes of porcine corneal structures from 25 to 90 degrees C using second harmonic generation (SHG) microscopy. Our results show that porcine stroma undergoes several distinct stages of structural changes between 25 and 90 degrees C. A decrease in SHG intensity from 30 to 45 degrees C and the existence of SHG intensity peaks at 53, 65, and 77 degrees C correlate to distinct structural alterations of the corneal stroma. At higher temperatures, the SHG intensity decreases and a baseline in SHG signal is reached at 90 degrees C. Our results demonstrate that SHG microscopy is a useful technique for obtaining qualitative and quantitative information of thermally treated corneal fibers without histological or labeling procedures. With additional developments, SHG imaging may be developed into an effective imaging technique for in vivo characterization of cornea structural changes.

Why it matters

OpenAlex reports 47 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We characterize the structural changes of porcine corneal structures from 25 to 90 degrees C using second harmonic generation (SHG) microscopy. Our results show that porcine stroma undergoes several distinct stages of structural changes between 25 and 90 degrees C. A decrease in SHG intensity from 30 to 45 degrees C and the existence of SHG intensity peaks at 53, 65, and 77 degrees C correlate to distinct structural alterations of the corneal stroma. At higher temperatures, the SHG intensity decreases and a baseline in SHG signal is reached at 90 degrees C. Our results demonstrate that SHG microscopy is a useful technique for obtaining qualitative and quantitative information of thermally treated corneal fibers without histological or labeling procedures. With additional developments, SHG imaging may be developed into an effective imaging technique for in vivo characterization of cornea structural changes.

Key concepts: Cornea, Second-harmonic generation, Stroma, Microscopy, Materials science, Second-harmonic imaging microscopy, Biophysics, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Characterizing the thermally induced structural changes to intact porcine eye, part 1: second harmonic generation imaging of cornea stroma — Research Paper | ScholarLens