2012Unpublished venueRequires access

Comparison of terahertz and infrared spectroscopy for degraded hydrocarbon liquid

Ryuichi Ogura, Zulkarnain Ahmad Noorden, Nguyễn Nhật Nam, Satoshi Matsumoto

Open publisher page 1 citations

Abstract

Terahertz (THz) spectroscopy has high sensitivity for the interaction between molecules and vibration of large molecules. Besides, it is well known that infrared (IR) spectroscopy can be used to detect the vibration of functional groups. Hence, the comparison of the conventional diagnosis method using IR spectroscopy and THz spectroscopy is expected for more potential diagnosis. In this study, the comparison between THz spectroscopy and IR spectroscopy for deteriorated hydrocarbon liquids has been conducted for the degraded insulating oils. The surveyed samples are pure dodecane and mineral oil. The degraded samples are made by heating in the oxygen atmosphere. In addition, we also measured the breakdown voltage and the volume resistivity to know the states of degraded insulating oil. The experimental results show that oxidation causes spectral changes in the both of THz and IR regions. The spectral change in the IR region is due to carbonyl group and hydroxyl group vibrations. Whereas, in the THz region, the spectral change originates from the modification of intermolecular interaction. The degradation phenomena of the insulating oil contribute to higher carbonyl/hydroxyl content and associated by stronger intermolecular interaction that leads to its lower breakdown voltage.

About this research paper

What this paper is about

Terahertz (THz) spectroscopy has high sensitivity for the interaction between molecules and vibration of large molecules. Besides, it is well known that infrared (IR) spectroscopy can be used to detect the vibration of functional groups. Hence, the comparison of the conventional diagnosis method using IR spectroscopy and THz spectroscopy is expected for more potential diagnosis. In this study, the comparison between THz spectroscopy and IR spectroscopy for deteriorated hydrocarbon liquids has been conducted for the degraded insulating oils. The surveyed samples are pure dodecane and mineral oil. The degraded samples are made by heating in the oxygen atmosphere. In addition, we also measured the breakdown voltage and the volume resistivity to know the states of degraded insulating oil. The experimental results show that oxidation causes spectral changes in the both of THz and IR regions. The spectral change in the IR region is due to carbonyl group and hydroxyl group vibrations. Whereas, in the THz region, the spectral change originates from the modification of intermolecular interaction. The degradation phenomena of the insulating oil contribute to higher carbonyl/hydroxyl content and associated by stronger intermolecular interaction that leads to its lower breakdown voltage.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Terahertz (THz) spectroscopy has high sensitivity for the interaction between molecules and vibration of large molecules. Besides, it is well known that infrared (IR) spectroscopy can be used to detect the vibration of functional groups. Hence, the comparison of the conventional diagnosis method using IR spectroscopy and THz spectroscopy is expected for more potential diagnosis. In this study, the comparison between THz spectroscopy and IR spectroscopy for deteriorated hydrocarbon liquids has been conducted for the degraded insulating oils. The surveyed samples are pure dodecane and mineral oil. The degraded samples are made by heating in the oxygen atmosphere. In addition, we also measured the breakdown voltage and the volume resistivity to know the states of degraded insulating oil. The experimental results show that oxidation causes spectral changes in the both of THz and IR regions. The spectral change in the IR region is due to carbonyl group and hydroxyl group vibrations. Whereas, in the THz region, the spectral change originates from the modification of intermolecular interaction. The degradation phenomena of the insulating oil contribute to higher carbonyl/hydroxyl content and associated by stronger intermolecular interaction that leads to its lower breakdown voltage.

Key concepts: Spectroscopy, Infrared spectroscopy, Terahertz radiation, Terahertz spectroscopy and technology, Infrared, Intermolecular force, Materials science, Dodecane

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of terahertz and infrared spectroscopy for degraded hydrocarbon liquid — Research Paper | ScholarLens