2013•British Journal of RadiologyOpen access

Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI

C Buchbender, Verena Hartung-Knemeyer, Michael Forsting, Gerald Antoch, Till Alexander Heusner

Open full text 40 citations

Abstract

OBJECTIVE: To compare the effect of implanted medical materials on (18)F-fludeoxyglucose ((18)F-FDG) positron emission tomography (PET)/MRI using a Dixon-based segmentation method for MRI-based attenuation correction (MRAC), PET/CT and CT-based attenuation-corrected PET (PETCTAC). METHODS: 12 patients (8 males and 4 females; age 58±11 years) with implanted medical materials prospectively underwent whole-body (18)F-FDG PET/CT and PET/MRI. CT, MRI and MRAC maps as well as PETCTAC and PETMRAC images were reviewed for the presence of artefacts. Their morphology and effect on the estimation of the (18)F-FDG uptake (no effect, underestimation, overestimation compared with non-corrected images) were compared. In PETMRAC images, a volume of interest was drawn in the area of the artefact and in a reference site (contralateral body part); the mean and maximum standardised uptake values (SUVmean; SUVmax) were measured. RESULTS: Of 27 implanted materials (20 dental fillings, 3 injection ports, 3 hip prostheses and 1 sternal cerclage), 27 (100%) caused artefacts in CT, 19 (70%) in T1 weighted MRI and 17 (63%) in MRAC maps. 20 (74%) caused a visual overestimation of the (18)F-FDG uptake in PETCTAC, 2 (7%) caused an underestimation and 5 (19%) had no effect. In PETMRAC, 19 (70%) caused spherical extinctions and 8 (30%) had no effect. Mean values for SUVmean and SUVmax were significantly decreased in artefact-harbouring sites (p<0.001). CONCLUSION: Contrary to PET attenuation correction artefacts in PET/CT, which often show an overestimation of the (18)F-FDG uptake, MRAC artefacts owing to implanted medical materials in most cases cause an underestimation. ADVANCES IN KNOWLEDGE: Being aware of the morphology of artefacts owing to implanted medical materials avoids interpretation errors when reading PET/MRI.

About this research paper

What this paper is about

OBJECTIVE: To compare the effect of implanted medical materials on (18)F-fludeoxyglucose ((18)F-FDG) positron emission tomography (PET)/MRI using a Dixon-based segmentation method for MRI-based attenuation correction (MRAC), PET/CT and CT-based attenuation-corrected PET (PETCTAC). METHODS: 12 patients (8 males and 4 females; age 58±11 years) with implanted medical materials prospectively underwent whole-body (18)F-FDG PET/CT and PET/MRI. CT, MRI and MRAC maps as well as PETCTAC and PETMRAC images were reviewed for the presence of artefacts. Their morphology and effect on the estimation of the (18)F-FDG uptake (no effect, underestimation, overestimation compared with non-corrected images) were compared. In PETMRAC images, a volume of interest was drawn in the area of the artefact and in a reference site (contralateral body part); the mean and maximum standardised uptake values (SUVmean; SUVmax) were measured. RESULTS: Of 27 implanted materials (20 dental fillings, 3 injection ports, 3 hip prostheses and 1 sternal cerclage), 27 (100%) caused artefacts in CT, 19 (70%) in T1 weighted MRI and 17 (63%) in MRAC maps. 20 (74%) caused a visual overestimation of the (18)F-FDG uptake in PETCTAC, 2 (7%) caused an underestimation and 5 (19%) had no effect. In PETMRAC, 19 (70%) caused spherical extinctions and 8 (30%) had no effect. Mean values for SUVmean and SUVmax were significantly decreased in artefact-harbouring sites (p<0.001). CONCLUSION: Contrary to PET attenuation correction artefacts in PET/CT, which often show an overestimation of the (18)F-FDG uptake, MRAC artefacts owing to implanted medical materials in most cases cause an underestimation. ADVANCES IN KNOWLEDGE: Being aware of the morphology of artefacts owing to implanted medical materials avoids interpretation errors when reading PET/MRI.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To compare the effect of implanted medical materials on (18)F-fludeoxyglucose ((18)F-FDG) positron emission tomography (PET)/MRI using a Dixon-based segmentation method for MRI-based attenuation correction (MRAC), PET/CT and CT-based attenuation-corrected PET (PETCTAC). METHODS: 12 patients (8 males and 4 females; age 58±11 years) with implanted medical materials prospectively underwent whole-body (18)F-FDG PET/CT and PET/MRI. CT, MRI and MRAC maps as well as PETCTAC and PETMRAC images were reviewed for the presence of artefacts. Their morphology and effect on the estimation of the (18)F-FDG uptake (no effect, underestimation, overestimation compared with non-corrected images) were compared. In PETMRAC images, a volume of interest was drawn in the area of the artefact and in a reference site (contralateral body part); the mean and maximum standardised uptake values (SUVmean; SUVmax) were measured. RESULTS: Of 27 implanted materials (20 dental fillings, 3 injection ports, 3 hip prostheses and 1 sternal cerclage), 27 (100%) caused artefacts in CT, 19 (70%) in T1 weighted MRI and 17 (63%) in MRAC maps. 20 (74%) caused a visual overestimation of the (18)F-FDG uptake in PETCTAC, 2 (7%) caused an underestimation and 5 (19%) had no effect. In PETMRAC, 19 (70%) caused spherical extinctions and 8 (30%) had no effect. Mean values for SUVmean and SUVmax were significantly decreased in artefact-harbouring sites (p<0.001). CONCLUSION: Contrary to PET attenuation correction artefacts in PET/CT, which often show an overestimation of the (18)F-FDG uptake, MRAC artefacts owing to implanted medical materials in most cases cause an underestimation. ADVANCES IN KNOWLEDGE: Being aware of the morphology of artefacts owing to implanted medical materials avoids interpretation errors when reading PET/MRI.

Key concepts: Correction for attenuation, Nuclear medicine, Positron emission tomography, Medicine, PET-CT, Tomography, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI — Research Paper | ScholarLens