2009•IEEE Transactions on Industrial ElectronicsOpen access

Extended Operation of Cascade Multicell Converters Under Fault Condition

Pablo Lezana, Gabriel Ortiz

Open full text 218 citations

Abstract

Multilevel converters are an interesting alternative for high power drives, due to their good quality output signals. Despite their advantages, the large number of components required increases the fault probability. Among the multilevel topologies, the cascade multicell converter presents advantages when operating under internal fault conditions, due to its high modularity. Previous works proposed to compensate the unbalanced operation due to a fault by changing the canonical fundamental output phase shift to precalculated angles, depending on the fault condition. This solution assumes that, if the maximum output phase voltage on each leg is used, the maximum line-to-line voltage will be at a maximum as well. This paper shows how this assumption is not always valid and presents the optimum angles and modulation indexes that must be used in order to obtain the maximum balanced load voltages.

About this research paper

What this paper is about

Multilevel converters are an interesting alternative for high power drives, due to their good quality output signals. Despite their advantages, the large number of components required increases the fault probability. Among the multilevel topologies, the cascade multicell converter presents advantages when operating under internal fault conditions, due to its high modularity. Previous works proposed to compensate the unbalanced operation due to a fault by changing the canonical fundamental output phase shift to precalculated angles, depending on the fault condition. This solution assumes that, if the maximum output phase voltage on each leg is used, the maximum line-to-line voltage will be at a maximum as well. This paper shows how this assumption is not always valid and presents the optimum angles and modulation indexes that must be used in order to obtain the maximum balanced load voltages.

Why it matters

OpenAlex reports 218 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Multilevel converters are an interesting alternative for high power drives, due to their good quality output signals. Despite their advantages, the large number of components required increases the fault probability. Among the multilevel topologies, the cascade multicell converter presents advantages when operating under internal fault conditions, due to its high modularity. Previous works proposed to compensate the unbalanced operation due to a fault by changing the canonical fundamental output phase shift to precalculated angles, depending on the fault condition. This solution assumes that, if the maximum output phase voltage on each leg is used, the maximum line-to-line voltage will be at a maximum as well. This paper shows how this assumption is not always valid and presents the optimum angles and modulation indexes that must be used in order to obtain the maximum balanced load voltages.

Key concepts: Cascade, Converters, Fault (geology), Control theory (sociology), Modularity (biology), Voltage, Network topology, Power (physics)