2008Acta ChromatographicaOpen access

Analysis of lovastatin in human plasma by liquid chromatography coupled with tandem mass spectrometry

Xixi Yu, Mantong Song, Taijun Hang, Aidong Wen

Open full text 2 citations

Abstract

A sensitive and selective liquid chromatographic tandem mass spectrometric (LC-MS-MS) method for analysis of lovastatin in human plasma has been developed and validated. Ethyl acetate extraction was used for plasma sample preparation and simvastatin was used as internal standard. Chromatographic separation was achieved on a C18 column by isocratic elution with 83:17:0.1 (v/v) methanol-2 μM aqueous sodium acetate-formic acid as mobile phase, delivered at 1.0 mL min−1. MS-MS detection was performed using positive electrospray ionization and multiple-reaction monitoring with argon for collision-induced dissociation. Calibration plots were generated over the concentration range 0.05 to 20 ng mL−1 (r > 0.999) with a lower limit of quantification (LLOQ) of 0.05 ng mL−1. Intra and inter-day precision and accuracy were determined at four different concentrations, 0.05, 0.5, 2.0, and 10.0 ng mL−1, and precision ranged from 0.4 to 11.4% with the deviation always less than 15% (n = 5). Extraction recoveries were from 86.8 to 94.1% for lovastatin and approximately 88.0% for simvastatin. The validated method was successfully applied to a bioequivalence study of two lovastatin tablets in 20 healthy volunteers.

Open-access reader

About this research paper

What this paper is about

A sensitive and selective liquid chromatographic tandem mass spectrometric (LC-MS-MS) method for analysis of lovastatin in human plasma has been developed and validated. Ethyl acetate extraction was used for plasma sample preparation and simvastatin was used as internal standard. Chromatographic separation was achieved on a C18 column by isocratic elution with 83:17:0.1 (v/v) methanol-2 μM aqueous sodium acetate-formic acid as mobile phase, delivered at 1.0 mL min−1. MS-MS detection was performed using positive electrospray ionization and multiple-reaction monitoring with argon for collision-induced dissociation. Calibration plots were generated over the concentration range 0.05 to 20 ng mL−1 (r > 0.999) with a lower limit of quantification (LLOQ) of 0.05 ng mL−1. Intra and inter-day precision and accuracy were determined at four different concentrations, 0.05, 0.5, 2.0, and 10.0 ng mL−1, and precision ranged from 0.4 to 11.4% with the deviation always less than 15% (n = 5). Extraction recoveries were from 86.8 to 94.1% for lovastatin and approximately 88.0% for simvastatin. The validated method was successfully applied to a bioequivalence study of two lovastatin tablets in 20 healthy volunteers.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive and selective liquid chromatographic tandem mass spectrometric (LC-MS-MS) method for analysis of lovastatin in human plasma has been developed and validated. Ethyl acetate extraction was used for plasma sample preparation and simvastatin was used as internal standard. Chromatographic separation was achieved on a C18 column by isocratic elution with 83:17:0.1 (v/v) methanol-2 μM aqueous sodium acetate-formic acid as mobile phase, delivered at 1.0 mL min−1. MS-MS detection was performed using positive electrospray ionization and multiple-reaction monitoring with argon for collision-induced dissociation. Calibration plots were generated over the concentration range 0.05 to 20 ng mL−1 (r > 0.999) with a lower limit of quantification (LLOQ) of 0.05 ng mL−1. Intra and inter-day precision and accuracy were determined at four different concentrations, 0.05, 0.5, 2.0, and 10.0 ng mL−1, and precision ranged from 0.4 to 11.4% with the deviation always less than 15% (n = 5). Extraction recoveries were from 86.8 to 94.1% for lovastatin and approximately 88.0% for simvastatin. The validated method was successfully applied to a bioequivalence study of two lovastatin tablets in 20 healthy volunteers.

Key concepts: Chemistry, Chromatography, Lovastatin, Liquid chromatography–mass spectrometry, Tandem mass spectrometry, Mass spectrometry, Human plasma, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of lovastatin in human plasma by liquid chromatography coupled with tandem mass spectrometry — Research Paper | ScholarLens