2004•Acta Oto-LaryngologicaRequires access

3D micro-CT images of ossicles destroyed by middle ear cholesteatoma

Keehyun Park, Sung‐Kyun Moon, Min Jung Cho, Ye Yeon Won, Myong‐Hyun Baek

Open publisher page 9 citations

Abstract

OBJECTIVES: To reconstruct the 3D structures of normal ossicles and ossicles destroyed by different cholesteatomas, and to compare the volume fractions of the two types of ossicles. MATERIALS AND METHOD: Thirteen pathological ossicles from four kinds of middle ear cholesteatoma obtained during surgery were used. Normal ossicles harvested from cadaveric temporal bone specimens were used as controls. The structures of the ossicles were analyzed using micro-CT by filming 2D cross-sectional images perpendicular to the long axis, from which 3D images were reconstructed. The volume fraction was measured using a CT-Analyzer and Ant. RESULTS: The volume fraction, indicating the relative strength of normal ossicles, was lower in the portion close to the articular surface. As the four types of cholesteatoma were found to express their patterns of destruction at various sites in the ossicles, they revealed a different volume fraction in each ossicle. CONCLUSION: Our preliminary data on ossicular structure obtained using micro-CT will be helpful for elucidating the normal and pathological structure of ossicles and for the further development of artificial prostheses.

About this research paper

What this paper is about

OBJECTIVES: To reconstruct the 3D structures of normal ossicles and ossicles destroyed by different cholesteatomas, and to compare the volume fractions of the two types of ossicles. MATERIALS AND METHOD: Thirteen pathological ossicles from four kinds of middle ear cholesteatoma obtained during surgery were used. Normal ossicles harvested from cadaveric temporal bone specimens were used as controls. The structures of the ossicles were analyzed using micro-CT by filming 2D cross-sectional images perpendicular to the long axis, from which 3D images were reconstructed. The volume fraction was measured using a CT-Analyzer and Ant. RESULTS: The volume fraction, indicating the relative strength of normal ossicles, was lower in the portion close to the articular surface. As the four types of cholesteatoma were found to express their patterns of destruction at various sites in the ossicles, they revealed a different volume fraction in each ossicle. CONCLUSION: Our preliminary data on ossicular structure obtained using micro-CT will be helpful for elucidating the normal and pathological structure of ossicles and for the further development of artificial prostheses.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To reconstruct the 3D structures of normal ossicles and ossicles destroyed by different cholesteatomas, and to compare the volume fractions of the two types of ossicles. MATERIALS AND METHOD: Thirteen pathological ossicles from four kinds of middle ear cholesteatoma obtained during surgery were used. Normal ossicles harvested from cadaveric temporal bone specimens were used as controls. The structures of the ossicles were analyzed using micro-CT by filming 2D cross-sectional images perpendicular to the long axis, from which 3D images were reconstructed. The volume fraction was measured using a CT-Analyzer and Ant. RESULTS: The volume fraction, indicating the relative strength of normal ossicles, was lower in the portion close to the articular surface. As the four types of cholesteatoma were found to express their patterns of destruction at various sites in the ossicles, they revealed a different volume fraction in each ossicle. CONCLUSION: Our preliminary data on ossicular structure obtained using micro-CT will be helpful for elucidating the normal and pathological structure of ossicles and for the further development of artificial prostheses.

Key concepts: Ossicles, Ossicle, Cholesteatoma, Anatomy, Middle ear, Cadaveric spasm, Medicine, Temporal bone

Related papers

Back to paper searchBrowse research topicsOriginal source
3D micro-CT images of ossicles destroyed by middle ear cholesteatoma — Research Paper | ScholarLens