2011Science and Technology for the Built EnvironmentRequires access

Design specifications for wet-bulb aspirator apparatus

Jacob P. Brenner, Gregory F. Nellis, Douglas T. Reindl

Open publisher page 4 citations

Abstract

Aspirated psychrometers are commonly used for the measurement of the wet-bulb temperature of a moist air stream. By knowing the wet-bulb temperature, dry-bulb temperature, and pressure, it is possible to determine the thermodynamic state of a moist air stream. ASHRAE Standards 41.6-1994 (ANSI/ASHRAE 2006) and 41.1 (ANSI/ASHRAE 1991) provide detailed design guidelines and considerations required to construct an aspirated psychrometer capable of measuring the wet-bulb temperature to within ±0.10°C (±0.18°F). This article documents the results of ASHRAE research project RP-1460 (2010), which had the objective of establishing design guidelines and considerations required to construct an aspirated psychrometer capable of measuring the wet-bulb temperature to within ±0.05°C (±0.09°F). First, an analytical model is presented and used to optimize an aspirated psychrometer and to predict the error in the measurement of the wet-bulb temperature over a range of conditions. Next, the details of an experimental apparatus are presented. The apparatus is used to verify the results of the analytical model and to establish the accuracy of the optimized psychrometer. Finally, conclusions are drawn as to the practicality of measuring the wet-bulb temperature to within ±0.05°C (±0.09°F).

About this research paper

What this paper is about

Aspirated psychrometers are commonly used for the measurement of the wet-bulb temperature of a moist air stream. By knowing the wet-bulb temperature, dry-bulb temperature, and pressure, it is possible to determine the thermodynamic state of a moist air stream. ASHRAE Standards 41.6-1994 (ANSI/ASHRAE 2006) and 41.1 (ANSI/ASHRAE 1991) provide detailed design guidelines and considerations required to construct an aspirated psychrometer capable of measuring the wet-bulb temperature to within ±0.10°C (±0.18°F). This article documents the results of ASHRAE research project RP-1460 (2010), which had the objective of establishing design guidelines and considerations required to construct an aspirated psychrometer capable of measuring the wet-bulb temperature to within ±0.05°C (±0.09°F). First, an analytical model is presented and used to optimize an aspirated psychrometer and to predict the error in the measurement of the wet-bulb temperature over a range of conditions. Next, the details of an experimental apparatus are presented. The apparatus is used to verify the results of the analytical model and to establish the accuracy of the optimized psychrometer. Finally, conclusions are drawn as to the practicality of measuring the wet-bulb temperature to within ±0.05°C (±0.09°F).

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aspirated psychrometers are commonly used for the measurement of the wet-bulb temperature of a moist air stream. By knowing the wet-bulb temperature, dry-bulb temperature, and pressure, it is possible to determine the thermodynamic state of a moist air stream. ASHRAE Standards 41.6-1994 (ANSI/ASHRAE 2006) and 41.1 (ANSI/ASHRAE 1991) provide detailed design guidelines and considerations required to construct an aspirated psychrometer capable of measuring the wet-bulb temperature to within ±0.10°C (±0.18°F). This article documents the results of ASHRAE research project RP-1460 (2010), which had the objective of establishing design guidelines and considerations required to construct an aspirated psychrometer capable of measuring the wet-bulb temperature to within ±0.05°C (±0.09°F). First, an analytical model is presented and used to optimize an aspirated psychrometer and to predict the error in the measurement of the wet-bulb temperature over a range of conditions. Next, the details of an experimental apparatus are presented. The apparatus is used to verify the results of the analytical model and to establish the accuracy of the optimized psychrometer. Finally, conclusions are drawn as to the practicality of measuring the wet-bulb temperature to within ±0.05°C (±0.09°F).

Key concepts: ASHRAE 90.1, Hygrometer, Wet-bulb temperature, Dry-bulb temperature, Psychrometrics, Environmental science, Bulb, Meteorology