Development of a Structure for Blast Wave Mitigation
Shiro Kubota, Tei Saburi, Tomotaka Homae, Yuji Wada, Yuji Ogata, Mitsuaki Iida, Hideki Hamashima, Katsumi Katoh
Abstract
Shiro Kubota, Tei Saburi, Tomotaka Homae, Yuji Wada, Yuji Ogata, Mitsuaki Iida, Hideki Hamashima, Katsumi Katoh
Abstract
Abstract The internal structure of a blast containment container has been developed and examined by experiments involving the explosion of a high explosive. A steel pipe was selected as an effective structure for blast mitigation, because it dramatically reduces the blast wave in the radial direction near the explosion source. To also reduce the blast wave in the axial direction, two types of model structures consisting of a steel pipe as the main part were examined by both high‐speed photography and pressure measurements of the blast waves. A 0.34‐scale internal structure was constructed by combining these structures. To induce a powerful mitigation effect, the internal structure was filled with a shock‐absorbing material. The peak pressures of C4 explosions in free air were obtained on the basis of the published blast wave data for TNT explosions in free air using an equivalent weight of 1.37. The peak pressures of the blast waves from the structures for all cases were compared with the blast wave data for C4 explosions in free air to estimate the blast mitigation effect. As a result it was estimated that the internal structure not only eliminates the blast pressure in the radial direction but also reduces the blast wave in the axial direction by 36 %. By combining the effects of the internal structure and the shock‐absorbing material, the structure can reduce the peak pressure by 75 %.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract The internal structure of a blast containment container has been developed and examined by experiments involving the explosion of a high explosive. A steel pipe was selected as an effective structure for blast mitigation, because it dramatically reduces the blast wave in the radial direction near the explosion source. To also reduce the blast wave in the axial direction, two types of model structures consisting of a steel pipe as the main part were examined by both high‐speed photography and pressure measurements of the blast waves. A 0.34‐scale internal structure was constructed by combining these structures. To induce a powerful mitigation effect, the internal structure was filled with a shock‐absorbing material. The peak pressures of C4 explosions in free air were obtained on the basis of the published blast wave data for TNT explosions in free air using an equivalent weight of 1.37. The peak pressures of the blast waves from the structures for all cases were compared with the blast wave data for C4 explosions in free air to estimate the blast mitigation effect. As a result it was estimated that the internal structure not only eliminates the blast pressure in the radial direction but also reduces the blast wave in the axial direction by 36 %. By combining the effects of the internal structure and the shock‐absorbing material, the structure can reduce the peak pressure by 75 %.
Key concepts: Blast wave, Explosive material, Air blast, Shock wave, Internal pressure, Shock (circulatory), Overpressure, Mechanics