2011•International Journal of PhytopharmacyOpen access

IMPROVED RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF STEVIOSIDE IN STEVIA REBAUDIANA BERTONI BURM

Shankar D. Katekhaye, Dhiraj Jadhao, Bhaskar Narayan Thorat

Open full text 9 citations

Abstract

An RP-HPLC method with UV array detection was established for the determination of stevioside, an extract of herbal S. rebaudiana plant . The stevioside was separated using isocratic solvent system consisting of methanol and 0.1% orthophosphoric acid (v/v) in water (70:30) at flow rate of 1.0 ml/min and the detection wavelength of 219 nm. The method was validated for linearity, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ). The linearity of the proposed method was obtained in the range of 5.0-75 μg/ml with regression coefficient of 0.9999. Intraday and interday precision studies showed the relative standard deviation less than 2.5%. The accuracy of the proposed method was determined by a recovery study conducted at 3 different levels. The average recovery was 97-99%. The LOD and LOQ were 0.02 and 0.05

About this research paper

What this paper is about

An RP-HPLC method with UV array detection was established for the determination of stevioside, an extract of herbal S. rebaudiana plant . The stevioside was separated using isocratic solvent system consisting of methanol and 0.1% orthophosphoric acid (v/v) in water (70:30) at flow rate of 1.0 ml/min and the detection wavelength of 219 nm. The method was validated for linearity, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ). The linearity of the proposed method was obtained in the range of 5.0-75 μg/ml with regression coefficient of 0.9999. Intraday and interday precision studies showed the relative standard deviation less than 2.5%. The accuracy of the proposed method was determined by a recovery study conducted at 3 different levels. The average recovery was 97-99%. The LOD and LOQ were 0.02 and 0.05

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An RP-HPLC method with UV array detection was established for the determination of stevioside, an extract of herbal S. rebaudiana plant . The stevioside was separated using isocratic solvent system consisting of methanol and 0.1% orthophosphoric acid (v/v) in water (70:30) at flow rate of 1.0 ml/min and the detection wavelength of 219 nm. The method was validated for linearity, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ). The linearity of the proposed method was obtained in the range of 5.0-75 μg/ml with regression coefficient of 0.9999. Intraday and interday precision studies showed the relative standard deviation less than 2.5%. The accuracy of the proposed method was determined by a recovery study conducted at 3 different levels. The average recovery was 97-99%. The LOD and LOQ were 0.02 and 0.05

Key concepts: Stevia rebaudiana, Stevioside, Stevia, Chromatography, Chemistry, Food science, Medicine, Alternative medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
IMPROVED RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF STEVIOSIDE IN STEVIA REBAUDIANA BERTONI BURM — Research Paper | ScholarLens