INTRAOPERATIVE USE OF HANDHELD SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING IN MACULAR SURGERY
Pouya N. Dayani, Ramiro S. Maldonado, Sina Farsiu, Cynthia A. Toth
Abstract
Pouya N. Dayani, Ramiro S. Maldonado, Sina Farsiu, Cynthia A. Toth
Abstract
In Brief Purpose: To describe the intraoperative use of handheld spectral domain optical coherence tomography (SDOCT) imaging in macular surgery. Design: Prospective, observational case series. Methods: A handheld SDOCT device was used to obtain preincision optical coherence tomography imaging in patients undergoing vitrectomy for macular diseases. After removal of the internal limiting membrane or the epiretinal membrane, repeat intraoperative imaging was obtained. Spectral domain optical coherence tomography findings were characterized. Results: An efficient technique was established for obtaining intraoperative SDOCT imaging. A total of eight patients were included in the study. Four patients underwent surgery for macular hole, three patients for epiretinal membrane, and one for vitreomacular traction. Comparison of the preincision and intraoperative SDOCT images demonstrated distinct changes in retinal contour and macular hole configuration. Intraoperative SDOCT imaging identified additional membranes in two patients. Conclusion: The intraoperative use of handheld SDOCT imaging provides an efficient method for visualizing macular pathology. This technology may, in certain cases, help confirm or identify diseases that may be difficult to visualize during surgery. The authors report the technique of obtaining intraoperative spectral domain optical coherence tomography imaging using a handheld probe. A total of eight adult patients undergoing macular surgery were enrolled. The intraoperative spectral domain optical coherence tomography images were characterized and compared with surgeon's assessment and with images obtained immediately before surgery.
OpenAlex reports 161 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In Brief Purpose: To describe the intraoperative use of handheld spectral domain optical coherence tomography (SDOCT) imaging in macular surgery. Design: Prospective, observational case series. Methods: A handheld SDOCT device was used to obtain preincision optical coherence tomography imaging in patients undergoing vitrectomy for macular diseases. After removal of the internal limiting membrane or the epiretinal membrane, repeat intraoperative imaging was obtained. Spectral domain optical coherence tomography findings were characterized. Results: An efficient technique was established for obtaining intraoperative SDOCT imaging. A total of eight patients were included in the study. Four patients underwent surgery for macular hole, three patients for epiretinal membrane, and one for vitreomacular traction. Comparison of the preincision and intraoperative SDOCT images demonstrated distinct changes in retinal contour and macular hole configuration. Intraoperative SDOCT imaging identified additional membranes in two patients. Conclusion: The intraoperative use of handheld SDOCT imaging provides an efficient method for visualizing macular pathology. This technology may, in certain cases, help confirm or identify diseases that may be difficult to visualize during surgery. The authors report the technique of obtaining intraoperative spectral domain optical coherence tomography imaging using a handheld probe. A total of eight adult patients undergoing macular surgery were enrolled. The intraoperative spectral domain optical coherence tomography images were characterized and compared with surgeon's assessment and with images obtained immediately before surgery.
Key concepts: Optical coherence tomography, Epiretinal membrane, Macular hole, Medicine, Vitrectomy, Pars plana, Ophthalmology, Tomography