1995IEEE Transactions on Industrial ElectronicsRequires access

A new UPS scheme provides harmonic suppression and input power factor correction

Jinn‐Chang Wu, Hurng‐Liahng Jou

Open publisher page 63 citations

Abstract

A new parallel processing uninterruptible power supply (UPS) configuration is proposed in this paper. It provides active power line conditioning to minimize mains current distortion. This performance is superior to a conventional UPS. A prototype has been implemented and tested to verify its performance. The experimental results show that the input power factor of the proposed UPS is nearly unity, and the total harmonic distortion (THD) of the input current under nonlinear loading is only 3.618% for a mains voltage with THD of 1.633%.

About this research paper

What this paper is about

A new parallel processing uninterruptible power supply (UPS) configuration is proposed in this paper. It provides active power line conditioning to minimize mains current distortion. This performance is superior to a conventional UPS. A prototype has been implemented and tested to verify its performance. The experimental results show that the input power factor of the proposed UPS is nearly unity, and the total harmonic distortion (THD) of the input current under nonlinear loading is only 3.618% for a mains voltage with THD of 1.633%.

Why it matters

OpenAlex reports 63 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new parallel processing uninterruptible power supply (UPS) configuration is proposed in this paper. It provides active power line conditioning to minimize mains current distortion. This performance is superior to a conventional UPS. A prototype has been implemented and tested to verify its performance. The experimental results show that the input power factor of the proposed UPS is nearly unity, and the total harmonic distortion (THD) of the input current under nonlinear loading is only 3.618% for a mains voltage with THD of 1.633%.

Key concepts: Total harmonic distortion, Power factor, Uninterruptible power supply, THD analyzer, Distortion (music), Control theory (sociology), Mains electricity, AC power

Related papers

Back to paper searchBrowse research topicsOriginal source
A new UPS scheme provides harmonic suppression and input power factor correction — Research Paper | ScholarLens