2009•Unpublished venueRequires access

Current conveyor based amplifier and adaptive buffer for use in an analog frontend

Georg Ellguth, S. Henker, Christian Mayr, René Schüffny

Open publisher page 2 citations

Abstract

We present an instrumentation amplifier based on second generation current conveyors (CCII+). The design is implemented in a 0.6 ¿m CMOS technology, incorporating several circuit techniques necessary for achieving high resolution at very low input signal levels. Compared to simulated results reported in recent literature, we show that in an actual silicon implementation, several detrimental circuit effects have to be countered. A conventional instrumentation amplifier and a buffer is used as second stage to match the high impedance output of the current conveyors to the low impedance input of an SC ADC. The buffer amplifier is composed of a conventional class A OTA, retrofitted with a positive feedback adaptive bias current supply, which offers class AB power and slew rate performance at class A linearity. Measurement results are given, showing the veracity of the approach.

About this research paper

What this paper is about

We present an instrumentation amplifier based on second generation current conveyors (CCII+). The design is implemented in a 0.6 ¿m CMOS technology, incorporating several circuit techniques necessary for achieving high resolution at very low input signal levels. Compared to simulated results reported in recent literature, we show that in an actual silicon implementation, several detrimental circuit effects have to be countered. A conventional instrumentation amplifier and a buffer is used as second stage to match the high impedance output of the current conveyors to the low impedance input of an SC ADC. The buffer amplifier is composed of a conventional class A OTA, retrofitted with a positive feedback adaptive bias current supply, which offers class AB power and slew rate performance at class A linearity. Measurement results are given, showing the veracity of the approach.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present an instrumentation amplifier based on second generation current conveyors (CCII+). The design is implemented in a 0.6 ¿m CMOS technology, incorporating several circuit techniques necessary for achieving high resolution at very low input signal levels. Compared to simulated results reported in recent literature, we show that in an actual silicon implementation, several detrimental circuit effects have to be countered. A conventional instrumentation amplifier and a buffer is used as second stage to match the high impedance output of the current conveyors to the low impedance input of an SC ADC. The buffer amplifier is composed of a conventional class A OTA, retrofitted with a positive feedback adaptive bias current supply, which offers class AB power and slew rate performance at class A linearity. Measurement results are given, showing the veracity of the approach.

Key concepts: Buffer amplifier, Current conveyor, Instrumentation amplifier, Slew rate, Amplifier, Electronic engineering, Current-feedback operational amplifier, Output impedance

Related papers

Back to paper searchBrowse research topicsOriginal source
Current conveyor based amplifier and adaptive buffer for use in an analog frontend — Research Paper | ScholarLens