2003•Journal of Applied Polymer ScienceOpen access

Study on the properties of crosslinking of poly(ethylene oxide) and hydroxyapatite–poly(ethylene oxide) composite

Raid Banat, Teoman Tinçer

Open full text 6 citations

Abstract

Abstract This study covers the crosslinking of poly(ethylene oxide) (PEO) and its composite with calcium hydroxyapatite (HA), their mechanical and swelling properties, and morphology. Sheets of the composites of PEO (two different grades with Mv: 5 × 106 and 2 × 105) and HA and neat PEO were prepared by compression molding. The prepared composite and PEO (0.1‐mm‐thick) sheets were crosslinked with exposure of UV‐irradiation in the presence of a photoinitiator, acetophenone (AP). This simple method for crosslinking, induced by UV‐irradiation in the presence of AP, yielded PEO with gel content up to 90%. Gel content, equilibrium swelling ratio, and mechanical and morphological properties of the low molecular weight polyethylene oxide (LMPEO)–HA crosslinked and uncrosslinked composites were evaluated. Although the inclusion of HA into LMPEO inhibits the extent of crosslinking, the LMPEO–HA composite with 20% HA by weight shows the highest gel content, with appreciable equilibrium swelling and mechanical strength. The growth of HA in simulated body fluid solutions on fractured surfaces of LMPEO and also LMPEO–HA was found to be very favorable within short times. The dimensional stability of these samples was found to be satisfactory after swelling and deposition experiments. The good compatibility between the filler hydroxyapatite and poly(ethylene oxide) makes this composite a useful tissue‐adhesive material. © 2003 Wiley Periodicals, Inc. J Appl Polym Sci 90: 488–496, 2003

About this research paper

What this paper is about

Abstract This study covers the crosslinking of poly(ethylene oxide) (PEO) and its composite with calcium hydroxyapatite (HA), their mechanical and swelling properties, and morphology. Sheets of the composites of PEO (two different grades with Mv: 5 × 106 and 2 × 105) and HA and neat PEO were prepared by compression molding. The prepared composite and PEO (0.1‐mm‐thick) sheets were crosslinked with exposure of UV‐irradiation in the presence of a photoinitiator, acetophenone (AP). This simple method for crosslinking, induced by UV‐irradiation in the presence of AP, yielded PEO with gel content up to 90%. Gel content, equilibrium swelling ratio, and mechanical and morphological properties of the low molecular weight polyethylene oxide (LMPEO)–HA crosslinked and uncrosslinked composites were evaluated. Although the inclusion of HA into LMPEO inhibits the extent of crosslinking, the LMPEO–HA composite with 20% HA by weight shows the highest gel content, with appreciable equilibrium swelling and mechanical strength. The growth of HA in simulated body fluid solutions on fractured surfaces of LMPEO and also LMPEO–HA was found to be very favorable within short times. The dimensional stability of these samples was found to be satisfactory after swelling and deposition experiments. The good compatibility between the filler hydroxyapatite and poly(ethylene oxide) makes this composite a useful tissue‐adhesive material. © 2003 Wiley Periodicals, Inc. J Appl Polym Sci 90: 488–496, 2003

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract This study covers the crosslinking of poly(ethylene oxide) (PEO) and its composite with calcium hydroxyapatite (HA), their mechanical and swelling properties, and morphology. Sheets of the composites of PEO (two different grades with Mv: 5 × 106 and 2 × 105) and HA and neat PEO were prepared by compression molding. The prepared composite and PEO (0.1‐mm‐thick) sheets were crosslinked with exposure of UV‐irradiation in the presence of a photoinitiator, acetophenone (AP). This simple method for crosslinking, induced by UV‐irradiation in the presence of AP, yielded PEO with gel content up to 90%. Gel content, equilibrium swelling ratio, and mechanical and morphological properties of the low molecular weight polyethylene oxide (LMPEO)–HA crosslinked and uncrosslinked composites were evaluated. Although the inclusion of HA into LMPEO inhibits the extent of crosslinking, the LMPEO–HA composite with 20% HA by weight shows the highest gel content, with appreciable equilibrium swelling and mechanical strength. The growth of HA in simulated body fluid solutions on fractured surfaces of LMPEO and also LMPEO–HA was found to be very favorable within short times. The dimensional stability of these samples was found to be satisfactory after swelling and deposition experiments. The good compatibility between the filler hydroxyapatite and poly(ethylene oxide) makes this composite a useful tissue‐adhesive material. © 2003 Wiley Periodicals, Inc. J Appl Polym Sci 90: 488–496, 2003

Key concepts: Swelling, Materials science, Ethylene oxide, Composite number, Composite material, Polyethylene, Compression molding, Photoinitiator

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the properties of crosslinking of poly(ethylene oxide) and hydroxyapatite–poly(ethylene oxide) composite — Research Paper | ScholarLens