1993Journal of Magnetic Resonance ImagingRequires access

Theoretical analysis of gadopentetate dimeglumine enhancement in T1‐weighted imaging of the brain: Comparison of two‐dimensional spin‐echo and three‐dimensional gradient‐echo sequences

John P. Mugler, James R. Brookeman

Open publisher page 54 citations

Abstract

By using a theoretical model, the signal difference-to-noise ratios between simulated lesions and normal white matter and gray matter were calculated as a function of lesion concentration of gadopentetate dimeglumine (GD) for two-dimensional (2D) T1-weighted spin-echo (SE), three-dimensional (3D) steady-state spoiled gradient-echo (GRE) (FLASH [fast low-angle shot]), and 3D magnetization-prepared rapid gradient echo (MP-RAGE) pulse sequences. The 3D GRE sequences provided greater contrast enhancement at relatively high [GD], and the 2D SE sequence demonstrated greater enhancement and a higher rate of enhancement at low [GD]. The results predict that at low [GD], certain lesions could probably be detected with the 2D SE sequence but possibly not with one or both of the 3D GRE sequences. At high [GD], certain lesions could probably be detected with one or both of the 3D GRE sequences but possibly not with the 2D SE sequence. This provides a potential explanation for the clinical observation that certain contrast agent-enhanced lesions appear less conspicuous on 3D GRE images than on 2D SE images and vice versa. Modified parameter values were derived for the 3D FLASH and 3D MP-RAGE sequences that are predicted to produce contrast enhancement behavior equivalent or superior to that of a conventional 2D SE sequence.

About this research paper

What this paper is about

By using a theoretical model, the signal difference-to-noise ratios between simulated lesions and normal white matter and gray matter were calculated as a function of lesion concentration of gadopentetate dimeglumine (GD) for two-dimensional (2D) T1-weighted spin-echo (SE), three-dimensional (3D) steady-state spoiled gradient-echo (GRE) (FLASH [fast low-angle shot]), and 3D magnetization-prepared rapid gradient echo (MP-RAGE) pulse sequences. The 3D GRE sequences provided greater contrast enhancement at relatively high [GD], and the 2D SE sequence demonstrated greater enhancement and a higher rate of enhancement at low [GD]. The results predict that at low [GD], certain lesions could probably be detected with the 2D SE sequence but possibly not with one or both of the 3D GRE sequences. At high [GD], certain lesions could probably be detected with one or both of the 3D GRE sequences but possibly not with the 2D SE sequence. This provides a potential explanation for the clinical observation that certain contrast agent-enhanced lesions appear less conspicuous on 3D GRE images than on 2D SE images and vice versa. Modified parameter values were derived for the 3D FLASH and 3D MP-RAGE sequences that are predicted to produce contrast enhancement behavior equivalent or superior to that of a conventional 2D SE sequence.

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

By using a theoretical model, the signal difference-to-noise ratios between simulated lesions and normal white matter and gray matter were calculated as a function of lesion concentration of gadopentetate dimeglumine (GD) for two-dimensional (2D) T1-weighted spin-echo (SE), three-dimensional (3D) steady-state spoiled gradient-echo (GRE) (FLASH [fast low-angle shot]), and 3D magnetization-prepared rapid gradient echo (MP-RAGE) pulse sequences. The 3D GRE sequences provided greater contrast enhancement at relatively high [GD], and the 2D SE sequence demonstrated greater enhancement and a higher rate of enhancement at low [GD]. The results predict that at low [GD], certain lesions could probably be detected with the 2D SE sequence but possibly not with one or both of the 3D GRE sequences. At high [GD], certain lesions could probably be detected with one or both of the 3D GRE sequences but possibly not with the 2D SE sequence. This provides a potential explanation for the clinical observation that certain contrast agent-enhanced lesions appear less conspicuous on 3D GRE images than on 2D SE images and vice versa. Modified parameter values were derived for the 3D FLASH and 3D MP-RAGE sequences that are predicted to produce contrast enhancement behavior equivalent or superior to that of a conventional 2D SE sequence.

Key concepts: Gradient echo, Pulse sequence, Nuclear magnetic resonance, Gadolinium, Spin echo, White matter, Flip angle, Contrast enhancement

Related papers

Back to paper searchBrowse research topicsOriginal source
Theoretical analysis of gadopentetate dimeglumine enhancement in T1‐weighted imaging of the brain: Comparison of two‐dimensional spin‐echo and three‐dimensional gradient‐echo sequences — Research Paper | ScholarLens