2008IEEE Transactions on Geoscience and Remote SensingRequires access

Radiometric Calibration of LIDAR Intensity With Commercially Available Reference Targets

Sanna Kaasalainen, Hannu Hyyppä, Antero Kukko, Paula Litkey, Eero Ahokas, Juha Hyyppä, Hubert Lehner, Anttoni Jaakkola, Juha Suomalainen, Anu Akujärvi, M. Kaasalainen, Ulla Pyysalo

Open publisher page 134 citations

Abstract

We present a new approach for radiometric calibration of light detection and ranging (LIDAR) intensity data and demonstrate an application of this method to natural targets. The method is based on 1) using commercially available sand and gravel as reference targets and 2) the calibration of these reference targets in the laboratory conditions to know their backscatter properties. We have investigated the target properties crucial for accurate and consistent reflectance calibration and present a set of ideal targets easily available for calibration purposes. The first results from LIDAR-based brightness measurement of grass and sand show that the gravel-based calibration approach works in practice, is cost effective, and produces statistically meaningful results: Comparison of results from two separate airborne laser scanning campaigns shows that the relative calibration produces repeatable reflectance values.

About this research paper

What this paper is about

We present a new approach for radiometric calibration of light detection and ranging (LIDAR) intensity data and demonstrate an application of this method to natural targets. The method is based on 1) using commercially available sand and gravel as reference targets and 2) the calibration of these reference targets in the laboratory conditions to know their backscatter properties. We have investigated the target properties crucial for accurate and consistent reflectance calibration and present a set of ideal targets easily available for calibration purposes. The first results from LIDAR-based brightness measurement of grass and sand show that the gravel-based calibration approach works in practice, is cost effective, and produces statistically meaningful results: Comparison of results from two separate airborne laser scanning campaigns shows that the relative calibration produces repeatable reflectance values.

Why it matters

OpenAlex reports 134 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present a new approach for radiometric calibration of light detection and ranging (LIDAR) intensity data and demonstrate an application of this method to natural targets. The method is based on 1) using commercially available sand and gravel as reference targets and 2) the calibration of these reference targets in the laboratory conditions to know their backscatter properties. We have investigated the target properties crucial for accurate and consistent reflectance calibration and present a set of ideal targets easily available for calibration purposes. The first results from LIDAR-based brightness measurement of grass and sand show that the gravel-based calibration approach works in practice, is cost effective, and produces statistically meaningful results: Comparison of results from two separate airborne laser scanning campaigns shows that the relative calibration produces repeatable reflectance values.

Key concepts: Remote sensing, Lidar, Calibration, Ranging, Backscatter (email), Brightness, Environmental science, Radiometric calibration

Related papers

Back to paper searchBrowse research topicsOriginal source
Radiometric Calibration of LIDAR Intensity With Commercially Available Reference Targets — Research Paper | ScholarLens