2012NeurologyOpen access

Deconditioning in patients with orthostatic intolerance

Ajay K. Parsaik, Thomas G. Allison, Wolfgang Singer, David M. Sletten, Michael J. Joyner, Eduardo E. Benarroch, Phillip A. Low, Paola Sandroni

Open full text 112 citations

Abstract

OBJECTIVE: To study the frequency and degree of deconditioning, clinical features, and relationship between deconditioning and autonomic parameters in patients with orthostatic intolerance. METHODS: We retrospectively studied all patients seen for orthostatic intolerance at Mayo Clinic between January 2006 and June 2011, who underwent both standardized autonomic and exercise testing. RESULTS: A total of 184 patients (84 with postural orthostatic tachycardia syndrome [POTS] and 100 without orthostatic tachycardia) fulfilled the inclusion criteria. Of these, 89% were women, and median age was 27.5 years (interquartile range [IQR] 22-37 years). Symptom duration was 4 years (IQR 2-7.8). Of the patients, 90% had deconditioning (reduced maximum oxygen uptake [VO(2max)%] <85%) during exercise. This finding was unrelated to age, gender, or duration of illness. The prevalence of deconditioning was similar between those with POTS (95%) and those with orthostatic intolerance (91%). VO(2max)% had a weak correlation with a few autonomic and laboratory parameters but adequate predictors of VO(2max)% could not be identified. CONCLUSION: Reduced VO(2max)% consistent with deconditioning is present in almost all patients with orthostatic intolerance and may play a central role in pathophysiology. This finding provides a strong rationale for retraining in the treatment of orthostatic intolerance. None of the autonomic indices are reliable predictors of deconditioning.

Open-access reader

About this research paper

What this paper is about

OBJECTIVE: To study the frequency and degree of deconditioning, clinical features, and relationship between deconditioning and autonomic parameters in patients with orthostatic intolerance. METHODS: We retrospectively studied all patients seen for orthostatic intolerance at Mayo Clinic between January 2006 and June 2011, who underwent both standardized autonomic and exercise testing. RESULTS: A total of 184 patients (84 with postural orthostatic tachycardia syndrome [POTS] and 100 without orthostatic tachycardia) fulfilled the inclusion criteria. Of these, 89% were women, and median age was 27.5 years (interquartile range [IQR] 22-37 years). Symptom duration was 4 years (IQR 2-7.8). Of the patients, 90% had deconditioning (reduced maximum oxygen uptake [VO(2max)%] <85%) during exercise. This finding was unrelated to age, gender, or duration of illness. The prevalence of deconditioning was similar between those with POTS (95%) and those with orthostatic intolerance (91%). VO(2max)% had a weak correlation with a few autonomic and laboratory parameters but adequate predictors of VO(2max)% could not be identified. CONCLUSION: Reduced VO(2max)% consistent with deconditioning is present in almost all patients with orthostatic intolerance and may play a central role in pathophysiology. This finding provides a strong rationale for retraining in the treatment of orthostatic intolerance. None of the autonomic indices are reliable predictors of deconditioning.

Why it matters

OpenAlex reports 112 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To study the frequency and degree of deconditioning, clinical features, and relationship between deconditioning and autonomic parameters in patients with orthostatic intolerance. METHODS: We retrospectively studied all patients seen for orthostatic intolerance at Mayo Clinic between January 2006 and June 2011, who underwent both standardized autonomic and exercise testing. RESULTS: A total of 184 patients (84 with postural orthostatic tachycardia syndrome [POTS] and 100 without orthostatic tachycardia) fulfilled the inclusion criteria. Of these, 89% were women, and median age was 27.5 years (interquartile range [IQR] 22-37 years). Symptom duration was 4 years (IQR 2-7.8). Of the patients, 90% had deconditioning (reduced maximum oxygen uptake [VO(2max)%] <85%) during exercise. This finding was unrelated to age, gender, or duration of illness. The prevalence of deconditioning was similar between those with POTS (95%) and those with orthostatic intolerance (91%). VO(2max)% had a weak correlation with a few autonomic and laboratory parameters but adequate predictors of VO(2max)% could not be identified. CONCLUSION: Reduced VO(2max)% consistent with deconditioning is present in almost all patients with orthostatic intolerance and may play a central role in pathophysiology. This finding provides a strong rationale for retraining in the treatment of orthostatic intolerance. None of the autonomic indices are reliable predictors of deconditioning.

Key concepts: Orthostatic intolerance, Deconditioning, Medicine, Orthostatic vital signs, Postural Orthostatic Tachycardia Syndrome, Physical therapy, Exercise intolerance, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Deconditioning in patients with orthostatic intolerance — Research Paper | ScholarLens