Electrochemical Reduction behaviour of Donepezil at β-Cyclodextrin Modified Carbon Paste Electrode
C. Narasimha Rao, K. Subbarayudu, P. Venkateswarlu
Abstract
C. Narasimha Rao, K. Subbarayudu, P. Venkateswarlu
Abstract
A simple, accurate and sensitive voltammetric method for determination of donepezil (DNZ) using β-cyclodextrin modified carbon paste electrode (CDMCPE) is developed. CDMCPE exhibited significantly increased sensitivity and selectivity for DNZ compared to the bare carbon paste electrode (CPE). Effect of accumulation potential, accumulation time, pH of buffer, etc., on peak currents for the determination of DNZ was studied using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Peak currents showed a linear response in the concentration range 4.2 x 10-8 to 5.6 x10-7 M and 3.2 x 10-9 to 4.2 x 10-8 M at CPE and CDMCPE respectively. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 1.2 x 10-9 and 0.40 x 10-8 M. The proposed method has been successfully applied for the determination of DNZ in spiked urine samples, serum samples and pharmaceutical formulations.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple, accurate and sensitive voltammetric method for determination of donepezil (DNZ) using β-cyclodextrin modified carbon paste electrode (CDMCPE) is developed. CDMCPE exhibited significantly increased sensitivity and selectivity for DNZ compared to the bare carbon paste electrode (CPE). Effect of accumulation potential, accumulation time, pH of buffer, etc., on peak currents for the determination of DNZ was studied using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Peak currents showed a linear response in the concentration range 4.2 x 10-8 to 5.6 x10-7 M and 3.2 x 10-9 to 4.2 x 10-8 M at CPE and CDMCPE respectively. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 1.2 x 10-9 and 0.40 x 10-8 M. The proposed method has been successfully applied for the determination of DNZ in spiked urine samples, serum samples and pharmaceutical formulations.
Key concepts: Detection limit, Differential pulse voltammetry, Carbon paste electrode, Electrode, Electrochemistry, Cyclic voltammetry, Selectivity, Chemistry