2004IEEE Transactions on MagneticsRequires access

Effect of Patterned Magnetic Shields on High-Frequency Integrated Inductors

A.M. Crawford, S.X. Wang

Open publisher page 24 citations

Abstract

Understanding the losses in magnetic integrated inductors is essential for attaining optimal performance. Integrated inductors with thick magnetic shield (MS) with eddy current inhibiting slots were fabricated to understand the losses due to the MS, patterning, and eddy currents. An increase in the quality factor was measured for inductors with patterned magnetic shields. We further measured a) only a partial inhibition of eddy currents in films, and b) an increased in the expected frequency response of the magnetic material (in-situ). We found that patterning the MS with wide patterns (36 /spl mu/m wide) is not entirely sufficient for eliminating eddy currents, and the pattern should be refined; however studies of arrays of bars show that refining the pattern leads to dramatically different high frequency behavior that must be accounted for when optimizing the quality factor.

About this research paper

What this paper is about

Understanding the losses in magnetic integrated inductors is essential for attaining optimal performance. Integrated inductors with thick magnetic shield (MS) with eddy current inhibiting slots were fabricated to understand the losses due to the MS, patterning, and eddy currents. An increase in the quality factor was measured for inductors with patterned magnetic shields. We further measured a) only a partial inhibition of eddy currents in films, and b) an increased in the expected frequency response of the magnetic material (in-situ). We found that patterning the MS with wide patterns (36 /spl mu/m wide) is not entirely sufficient for eliminating eddy currents, and the pattern should be refined; however studies of arrays of bars show that refining the pattern leads to dramatically different high frequency behavior that must be accounted for when optimizing the quality factor.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Understanding the losses in magnetic integrated inductors is essential for attaining optimal performance. Integrated inductors with thick magnetic shield (MS) with eddy current inhibiting slots were fabricated to understand the losses due to the MS, patterning, and eddy currents. An increase in the quality factor was measured for inductors with patterned magnetic shields. We further measured a) only a partial inhibition of eddy currents in films, and b) an increased in the expected frequency response of the magnetic material (in-situ). We found that patterning the MS with wide patterns (36 /spl mu/m wide) is not entirely sufficient for eliminating eddy currents, and the pattern should be refined; however studies of arrays of bars show that refining the pattern leads to dramatically different high frequency behavior that must be accounted for when optimizing the quality factor.

Key concepts: Inductor, Eddy current, Shields, Materials science, Shield, Q factor, Nuclear magnetic resonance, Skin effect