2012International Journal of Computer ApplicationsOpen access

Effects of Openings in Shear Wall on Seismic Response of Structures

Sharmin RezaChowdhury, Mahadzir Abdul Rahman, M. J. Islam, Abhijit K. Das

Open full text 24 citations

Abstract

Finite Element Modeling now a days is an essentital approach in analysisng and simulating civil engineering problem numerically.In this paper at attempt is made to apply the finite element modelling in analysing and exploring the behavior of shear wall with opening under seismis load actions.In modern tall buildings, shear walls are commonly used as a vertical structural element for resisting the lateral loads that may be induced by the effect of wind and earthquakes.Shear walls are generally located at the sides of buildings or arranged in the form of core that houses stairs and lifts.Due to functional requirements such as doors, windows, and other openings, a shear wall in a building contains many openings.The size and location of openings may vary from architectural and functional point of view.In most of the apartment building, size and location of openings in shear wall are made without considering its effect on structural behavior of the building.This study is carried out on 6-story frame-shear wall buildings, using linear elastic analysis with the help of finite element software, ETABS under earthquake loads in equivalent static analysis.The results reveal that stiffness as well as seismic responses of structures is affected by the size of the openings as well as their locations in shear wall.It is also explored that top lateral drift of the system can also be reduced thickening the element in the model around the opening of shear wall.

Open-access reader

About this research paper

What this paper is about

Finite Element Modeling now a days is an essentital approach in analysisng and simulating civil engineering problem numerically.In this paper at attempt is made to apply the finite element modelling in analysing and exploring the behavior of shear wall with opening under seismis load actions.In modern tall buildings, shear walls are commonly used as a vertical structural element for resisting the lateral loads that may be induced by the effect of wind and earthquakes.Shear walls are generally located at the sides of buildings or arranged in the form of core that houses stairs and lifts.Due to functional requirements such as doors, windows, and other openings, a shear wall in a building contains many openings.The size and location of openings may vary from architectural and functional point of view.In most of the apartment building, size and location of openings in shear wall are made without considering its effect on structural behavior of the building.This study is carried out on 6-story frame-shear wall buildings, using linear elastic analysis with the help of finite element software, ETABS under earthquake loads in equivalent static analysis.The results reveal that stiffness as well as seismic responses of structures is affected by the size of the openings as well as their locations in shear wall.It is also explored that top lateral drift of the system can also be reduced thickening the element in the model around the opening of shear wall.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Finite Element Modeling now a days is an essentital approach in analysisng and simulating civil engineering problem numerically.In this paper at attempt is made to apply the finite element modelling in analysing and exploring the behavior of shear wall with opening under seismis load actions.In modern tall buildings, shear walls are commonly used as a vertical structural element for resisting the lateral loads that may be induced by the effect of wind and earthquakes.Shear walls are generally located at the sides of buildings or arranged in the form of core that houses stairs and lifts.Due to functional requirements such as doors, windows, and other openings, a shear wall in a building contains many openings.The size and location of openings may vary from architectural and functional point of view.In most of the apartment building, size and location of openings in shear wall are made without considering its effect on structural behavior of the building.This study is carried out on 6-story frame-shear wall buildings, using linear elastic analysis with the help of finite element software, ETABS under earthquake loads in equivalent static analysis.The results reveal that stiffness as well as seismic responses of structures is affected by the size of the openings as well as their locations in shear wall.It is also explored that top lateral drift of the system can also be reduced thickening the element in the model around the opening of shear wall.

Key concepts: Computer science, Shear wall, Shear (geology), Geology, Structural engineering, Paleontology, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of Openings in Shear Wall on Seismic Response of Structures — Research Paper | ScholarLens