2008Circulation Cardiovascular ImagingRequires access

A Study of Functional Anatomy of Aortic-Mitral Valve Coupling Using 3D Matrix Transesophageal Echocardiography

Federico Veronesi, Cristiana Corsi, Lissa Sugeng, Victor Mor‐Avi, Enrico G. Caiani, Lynn Weinert, C. Lamberti, Roberto M. Lang

Open publisher page 128 citations

Abstract

BACKGROUND: Mitral and aortic valves are known to be coupled via fibrous tissue connecting the two annuli. Previous studies evaluating this coupling have been limited to experimental animals using invasive techniques. The new matrix array transesophageal transducer provides high-resolution real-time 3D images of both valves simultaneously. We sought to develop and test a technique for quantitative assessment of mitral and aortic valve dynamics and coupling. METHODS AND RESULTS: Matrix array transesophageal (Philips iE33) imaging was performed in 24 patients with normal valves who underwent clinically indicated transesophageal echocardiography. Custom software was used to detect and track the mitral and aortic annuli in 3D space throughout the cardiac cycle, allowing automated measurement of changes in mitral and aortic valve morphology. Mitral annulus surface area and aortic annulus projected area changed reciprocally over time. Mitral annulus surface area was 8.0+/-2.1 cm(2) at end-diastole and decreased to 7.7+/-2.1 cm(2) in systole, reaching its maximum (10.0+/-2.2 cm(2)) at mitral valve opening. Aortic annulus projected area was 4.1+/-1.2 cm(2) at end-diastole, then increased during isovolumic contraction reaching its maximum (4.8+/-1.3 cm(2)) in the first third of systole and its minimum (3.6+/-1.0 cm(2)) during isovolumic relaxation. The angle between the mitral and aortic annuli was maximum (136+/-13 degrees ) at end-diastole and decreased to its minimum value (129+/-11 degrees ) during systole. CONCLUSIONS: This is the first study to report quantitative 3D assessment of the mitral and aortic valve dynamics from matrix array transesophageal images and describe the mitral-aortic coupling in a beating human heart. This ability may have impact on patient evaluation for valvular surgical interventions and prosthesis design.

About this research paper

What this paper is about

BACKGROUND: Mitral and aortic valves are known to be coupled via fibrous tissue connecting the two annuli. Previous studies evaluating this coupling have been limited to experimental animals using invasive techniques. The new matrix array transesophageal transducer provides high-resolution real-time 3D images of both valves simultaneously. We sought to develop and test a technique for quantitative assessment of mitral and aortic valve dynamics and coupling. METHODS AND RESULTS: Matrix array transesophageal (Philips iE33) imaging was performed in 24 patients with normal valves who underwent clinically indicated transesophageal echocardiography. Custom software was used to detect and track the mitral and aortic annuli in 3D space throughout the cardiac cycle, allowing automated measurement of changes in mitral and aortic valve morphology. Mitral annulus surface area and aortic annulus projected area changed reciprocally over time. Mitral annulus surface area was 8.0+/-2.1 cm(2) at end-diastole and decreased to 7.7+/-2.1 cm(2) in systole, reaching its maximum (10.0+/-2.2 cm(2)) at mitral valve opening. Aortic annulus projected area was 4.1+/-1.2 cm(2) at end-diastole, then increased during isovolumic contraction reaching its maximum (4.8+/-1.3 cm(2)) in the first third of systole and its minimum (3.6+/-1.0 cm(2)) during isovolumic relaxation. The angle between the mitral and aortic annuli was maximum (136+/-13 degrees ) at end-diastole and decreased to its minimum value (129+/-11 degrees ) during systole. CONCLUSIONS: This is the first study to report quantitative 3D assessment of the mitral and aortic valve dynamics from matrix array transesophageal images and describe the mitral-aortic coupling in a beating human heart. This ability may have impact on patient evaluation for valvular surgical interventions and prosthesis design.

Why it matters

OpenAlex reports 128 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Mitral and aortic valves are known to be coupled via fibrous tissue connecting the two annuli. Previous studies evaluating this coupling have been limited to experimental animals using invasive techniques. The new matrix array transesophageal transducer provides high-resolution real-time 3D images of both valves simultaneously. We sought to develop and test a technique for quantitative assessment of mitral and aortic valve dynamics and coupling. METHODS AND RESULTS: Matrix array transesophageal (Philips iE33) imaging was performed in 24 patients with normal valves who underwent clinically indicated transesophageal echocardiography. Custom software was used to detect and track the mitral and aortic annuli in 3D space throughout the cardiac cycle, allowing automated measurement of changes in mitral and aortic valve morphology. Mitral annulus surface area and aortic annulus projected area changed reciprocally over time. Mitral annulus surface area was 8.0+/-2.1 cm(2) at end-diastole and decreased to 7.7+/-2.1 cm(2) in systole, reaching its maximum (10.0+/-2.2 cm(2)) at mitral valve opening. Aortic annulus projected area was 4.1+/-1.2 cm(2) at end-diastole, then increased during isovolumic contraction reaching its maximum (4.8+/-1.3 cm(2)) in the first third of systole and its minimum (3.6+/-1.0 cm(2)) during isovolumic relaxation. The angle between the mitral and aortic annuli was maximum (136+/-13 degrees ) at end-diastole and decreased to its minimum value (129+/-11 degrees ) during systole. CONCLUSIONS: This is the first study to report quantitative 3D assessment of the mitral and aortic valve dynamics from matrix array transesophageal images and describe the mitral-aortic coupling in a beating human heart. This ability may have impact on patient evaluation for valvular surgical interventions and prosthesis design.

Key concepts: Cardiology, Internal medicine, Medicine, Mitral valve

Related papers

Back to paper searchBrowse research topicsOriginal source
A Study of Functional Anatomy of Aortic-Mitral Valve Coupling Using 3D Matrix Transesophageal Echocardiography — Research Paper | ScholarLens