Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles
Arzu Şencan, Reşat Selbaş, Önder Kızılkan, Soteris A. Kalogirou
Abstract
Open-access reader
Arzu Şencan, Reşat Selbaş, Önder Kızılkan, Soteris A. Kalogirou
Abstract
Open-access reader
This paper presents a computer-based first law and exergy analysis applied to vapour compression refrigeration systems for determining subcooling and superheating effects of environmentally safe new refrigerants. Three refrigerants are considered: R134a, R407c and R410a. It is found that subcooling and superheating temperatures directly influence the system performance as both condenser and evaporator temperatures are affected. The thermodynamic properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Six ANNs were trained to predict various properties of the three refrigerants. The training and validation of the ANNs were performed with good accuracy. The correlation coefficient obtained when unknown data were used to the networks were found to be equal or very near to 1 which is very satisfactory. Additionally, the present methodology proved to be much better than the linear multiple regression analysis. From the analysis of the results it is found that condenser and evaporator temperatures have strong effects on coefficient of performance (COP) and system irreversibility. Also both subcooling and superheating affect the system performance. This effect is similar for R134a and R407c, and different for R410a. Copyright © 2005 John Wiley & Sons, Ltd.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper presents a computer-based first law and exergy analysis applied to vapour compression refrigeration systems for determining subcooling and superheating effects of environmentally safe new refrigerants. Three refrigerants are considered: R134a, R407c and R410a. It is found that subcooling and superheating temperatures directly influence the system performance as both condenser and evaporator temperatures are affected. The thermodynamic properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Six ANNs were trained to predict various properties of the three refrigerants. The training and validation of the ANNs were performed with good accuracy. The correlation coefficient obtained when unknown data were used to the networks were found to be equal or very near to 1 which is very satisfactory. Additionally, the present methodology proved to be much better than the linear multiple regression analysis. From the analysis of the results it is found that condenser and evaporator temperatures have strong effects on coefficient of performance (COP) and system irreversibility. Also both subcooling and superheating affect the system performance. This effect is similar for R134a and R407c, and different for R410a. Copyright © 2005 John Wiley & Sons, Ltd.
Key concepts: Subcooling, Refrigerant, Superheating, Condenser (optics), Thermodynamics, Vapor-compression refrigeration, Coefficient of performance, Refrigeration