2005International Journal of Energy ResearchOpen access

Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles

Arzu Şencan, Reşat Selbaş, Önder Kızılkan, Soteris A. Kalogirou

Open full text 31 citations

Abstract

This paper presents a computer-based first law and exergy analysis applied to vapour compression refrigeration systems for determining subcooling and superheating effects of environmentally safe new refrigerants. Three refrigerants are considered: R134a, R407c and R410a. It is found that subcooling and superheating temperatures directly influence the system performance as both condenser and evaporator temperatures are affected. The thermodynamic properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Six ANNs were trained to predict various properties of the three refrigerants. The training and validation of the ANNs were performed with good accuracy. The correlation coefficient obtained when unknown data were used to the networks were found to be equal or very near to 1 which is very satisfactory. Additionally, the present methodology proved to be much better than the linear multiple regression analysis. From the analysis of the results it is found that condenser and evaporator temperatures have strong effects on coefficient of performance (COP) and system irreversibility. Also both subcooling and superheating affect the system performance. This effect is similar for R134a and R407c, and different for R410a. Copyright © 2005 John Wiley & Sons, Ltd.

Open-access reader

About this research paper

What this paper is about

This paper presents a computer-based first law and exergy analysis applied to vapour compression refrigeration systems for determining subcooling and superheating effects of environmentally safe new refrigerants. Three refrigerants are considered: R134a, R407c and R410a. It is found that subcooling and superheating temperatures directly influence the system performance as both condenser and evaporator temperatures are affected. The thermodynamic properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Six ANNs were trained to predict various properties of the three refrigerants. The training and validation of the ANNs were performed with good accuracy. The correlation coefficient obtained when unknown data were used to the networks were found to be equal or very near to 1 which is very satisfactory. Additionally, the present methodology proved to be much better than the linear multiple regression analysis. From the analysis of the results it is found that condenser and evaporator temperatures have strong effects on coefficient of performance (COP) and system irreversibility. Also both subcooling and superheating affect the system performance. This effect is similar for R134a and R407c, and different for R410a. Copyright © 2005 John Wiley & Sons, Ltd.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents a computer-based first law and exergy analysis applied to vapour compression refrigeration systems for determining subcooling and superheating effects of environmentally safe new refrigerants. Three refrigerants are considered: R134a, R407c and R410a. It is found that subcooling and superheating temperatures directly influence the system performance as both condenser and evaporator temperatures are affected. The thermodynamic properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Six ANNs were trained to predict various properties of the three refrigerants. The training and validation of the ANNs were performed with good accuracy. The correlation coefficient obtained when unknown data were used to the networks were found to be equal or very near to 1 which is very satisfactory. Additionally, the present methodology proved to be much better than the linear multiple regression analysis. From the analysis of the results it is found that condenser and evaporator temperatures have strong effects on coefficient of performance (COP) and system irreversibility. Also both subcooling and superheating affect the system performance. This effect is similar for R134a and R407c, and different for R410a. Copyright © 2005 John Wiley & Sons, Ltd.

Key concepts: Subcooling, Refrigerant, Superheating, Condenser (optics), Thermodynamics, Vapor-compression refrigeration, Coefficient of performance, Refrigeration

Related papers

Back to paper searchBrowse research topicsOriginal source
Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles — Research Paper | ScholarLens