1995IEEE Electron Device LettersRequires access

Novel p-JFET embedded in silicon radiation detectors that avoids preamplifier feedback resistor

Marco Sampietro, L. Fasoli, P. Řehák, L. Strüder

Open publisher page 24 citations

Abstract

The paper describes the design and the performance of an original p-channel JFET embedded in the collecting anode of a silicon radiation detector. The choice of a p-channel transistor, whose gate-to-channel junction is forward biased by the leakage current from the detector, avoids the preamplifier feedback resistor and performs a continuous dc reset of the collected charge. The reported design, fully compatible with the detector fabrication, makes the operation of the detector extremely simple, ensures the best charge collection capability and leads to improved charge resolution. The first detector produced with this type of transistor has a resolution of 27 electrons rms in the measurement of the collected charge at room temperature for a pixel active area of about 0.1 mm/sup 2/, and of 22 electrons rms at T=210 K.>

About this research paper

What this paper is about

The paper describes the design and the performance of an original p-channel JFET embedded in the collecting anode of a silicon radiation detector. The choice of a p-channel transistor, whose gate-to-channel junction is forward biased by the leakage current from the detector, avoids the preamplifier feedback resistor and performs a continuous dc reset of the collected charge. The reported design, fully compatible with the detector fabrication, makes the operation of the detector extremely simple, ensures the best charge collection capability and leads to improved charge resolution. The first detector produced with this type of transistor has a resolution of 27 electrons rms in the measurement of the collected charge at room temperature for a pixel active area of about 0.1 mm/sup 2/, and of 22 electrons rms at T=210 K.>

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The paper describes the design and the performance of an original p-channel JFET embedded in the collecting anode of a silicon radiation detector. The choice of a p-channel transistor, whose gate-to-channel junction is forward biased by the leakage current from the detector, avoids the preamplifier feedback resistor and performs a continuous dc reset of the collected charge. The reported design, fully compatible with the detector fabrication, makes the operation of the detector extremely simple, ensures the best charge collection capability and leads to improved charge resolution. The first detector produced with this type of transistor has a resolution of 27 electrons rms in the measurement of the collected charge at room temperature for a pixel active area of about 0.1 mm/sup 2/, and of 22 electrons rms at T=210 K.>

Key concepts: JFET, Preamplifier, Detector, Resistor, Transistor, Optoelectronics, Electrical engineering, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Novel p-JFET embedded in silicon radiation detectors that avoids preamplifier feedback resistor — Research Paper | ScholarLens