1959Textile Research JournalRequires access

An Empirical Method for Estimating the Degree of Crystallinity of Native Cellulose Using the X-Ray Diffractometer

Leon Segal, Joseph J. Creely, Andrew Martin, Carl M. Conrad

Open publisher page 8,658 citations

Abstract

An empirical method for determining the crystallinity of native cellulose was studied with an x-ray diffractometer using the focusing and transmission techniques. The influence of fluctuations in the primary radiation and in the counting and recording processes have been determined. The intensity of the 002 interference and the amor phous scatter at 2θ = 18° was measured. The percent crystalline material in the total cellulose was expressed by an x-ray "crystallinity index." This was done for cotton cellulose decrystallized with aqueous solutions containing from 70% to nominally 100% ethylamine. The x-ray "crystallinity index" was correlated with acid hydrolysis crys tallinity, moisture regain, density, leveling-off degree of polymerization values, and infrared absorbance values for each sample. The results indicate that the crystallinity index is a time-saving empirical measure of relative crystallinity. The precision of the crystallinity index in terms of the several crystallinity criteria is given. Based on over 40 samples for which acid hydrolysis crystallinity values were available, the standard error was 6.5%.

About this research paper

What this paper is about

An empirical method for determining the crystallinity of native cellulose was studied with an x-ray diffractometer using the focusing and transmission techniques. The influence of fluctuations in the primary radiation and in the counting and recording processes have been determined. The intensity of the 002 interference and the amor phous scatter at 2θ = 18° was measured. The percent crystalline material in the total cellulose was expressed by an x-ray "crystallinity index." This was done for cotton cellulose decrystallized with aqueous solutions containing from 70% to nominally 100% ethylamine. The x-ray "crystallinity index" was correlated with acid hydrolysis crys tallinity, moisture regain, density, leveling-off degree of polymerization values, and infrared absorbance values for each sample. The results indicate that the crystallinity index is a time-saving empirical measure of relative crystallinity. The precision of the crystallinity index in terms of the several crystallinity criteria is given. Based on over 40 samples for which acid hydrolysis crystallinity values were available, the standard error was 6.5%.

Why it matters

OpenAlex reports 8658 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An empirical method for determining the crystallinity of native cellulose was studied with an x-ray diffractometer using the focusing and transmission techniques. The influence of fluctuations in the primary radiation and in the counting and recording processes have been determined. The intensity of the 002 interference and the amor phous scatter at 2θ = 18° was measured. The percent crystalline material in the total cellulose was expressed by an x-ray "crystallinity index." This was done for cotton cellulose decrystallized with aqueous solutions containing from 70% to nominally 100% ethylamine. The x-ray "crystallinity index" was correlated with acid hydrolysis crys tallinity, moisture regain, density, leveling-off degree of polymerization values, and infrared absorbance values for each sample. The results indicate that the crystallinity index is a time-saving empirical measure of relative crystallinity. The precision of the crystallinity index in terms of the several crystallinity criteria is given. Based on over 40 samples for which acid hydrolysis crystallinity values were available, the standard error was 6.5%.

Key concepts: Crystallinity, Diffractometer, Materials science, Cellulose, Degree of polymerization, Hydrolysis, Analytical Chemistry (journal), Polymerization

Related papers

Back to paper searchBrowse research topicsOriginal source
An Empirical Method for Estimating the Degree of Crystallinity of Native Cellulose Using the X-Ray Diffractometer — Research Paper | ScholarLens