2003•SAE technical papers on CD-ROM/SAE technical paper seriesRequires access

Two-Step Variable Valve Actuation for Fuel Economy, Emissions, and Performance

Mark Sellnau, Eric Rask

Open publisher page 83 citations

Abstract

Variable-Valve Actuation (VVA) provides improvements in engine efficiency, emissions, and performance by changing the valve lift and timing as a function of engine operating conditions. Two-Step VVA systems utilize two discrete valve-lift profiles and may be combined with continuously variable cam phasing. Two-Step VVA systems are relatively simple, low cost and easy to package on new and existing engines, and therefore, are attractive to engine manufacturers. The objective of this work was to optimize Two-Step system design and operation for maximum system benefits. An Early-Intake-Valve-Closing (EIVC) strategy was selected for warmed-up operating conditions, and a Late-Intake-Valve-Opening (LIVO) strategy was selected for the cold start. Engine modeling tools were used to fundamentally understand the thermodynamic and fluid mechanical processes involved. A procedure was developed to rapidly and automatically process engine simulations for a wide range of engine operating conditions and valve train parameters including valve lift, duration, and timing. Modeling results indicate that substantial improvements in fuel economy, NOx emissions, and performance can be achieved. Reduced cold-start HC emissions are also expected. A comparison to fully flexible VVA, Three-Step VVA, and dual-independent cam phasing (only) is presented.

About this research paper

What this paper is about

Variable-Valve Actuation (VVA) provides improvements in engine efficiency, emissions, and performance by changing the valve lift and timing as a function of engine operating conditions. Two-Step VVA systems utilize two discrete valve-lift profiles and may be combined with continuously variable cam phasing. Two-Step VVA systems are relatively simple, low cost and easy to package on new and existing engines, and therefore, are attractive to engine manufacturers. The objective of this work was to optimize Two-Step system design and operation for maximum system benefits. An Early-Intake-Valve-Closing (EIVC) strategy was selected for warmed-up operating conditions, and a Late-Intake-Valve-Opening (LIVO) strategy was selected for the cold start. Engine modeling tools were used to fundamentally understand the thermodynamic and fluid mechanical processes involved. A procedure was developed to rapidly and automatically process engine simulations for a wide range of engine operating conditions and valve train parameters including valve lift, duration, and timing. Modeling results indicate that substantial improvements in fuel economy, NOx emissions, and performance can be achieved. Reduced cold-start HC emissions are also expected. A comparison to fully flexible VVA, Three-Step VVA, and dual-independent cam phasing (only) is presented.

Why it matters

OpenAlex reports 83 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Variable-Valve Actuation (VVA) provides improvements in engine efficiency, emissions, and performance by changing the valve lift and timing as a function of engine operating conditions. Two-Step VVA systems utilize two discrete valve-lift profiles and may be combined with continuously variable cam phasing. Two-Step VVA systems are relatively simple, low cost and easy to package on new and existing engines, and therefore, are attractive to engine manufacturers. The objective of this work was to optimize Two-Step system design and operation for maximum system benefits. An Early-Intake-Valve-Closing (EIVC) strategy was selected for warmed-up operating conditions, and a Late-Intake-Valve-Opening (LIVO) strategy was selected for the cold start. Engine modeling tools were used to fundamentally understand the thermodynamic and fluid mechanical processes involved. A procedure was developed to rapidly and automatically process engine simulations for a wide range of engine operating conditions and valve train parameters including valve lift, duration, and timing. Modeling results indicate that substantial improvements in fuel economy, NOx emissions, and performance can be achieved. Reduced cold-start HC emissions are also expected. A comparison to fully flexible VVA, Three-Step VVA, and dual-independent cam phasing (only) is presented.

Key concepts: Variable (mathematics), Automotive engineering, Computer science, Environmental science, Engineering, Mathematical analysis, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Two-Step Variable Valve Actuation for Fuel Economy, Emissions, and Performance — Research Paper | ScholarLens