2009Journal of Separation ScienceRequires access

Polymeric strong cation‐exchange monolithic column for capillary liquid chromatography of peptides and proteins

Xin Chen, H. Dennis Tolley, Milton L. Lee

Open publisher page 28 citations

Abstract

A strong cation-exchange (SCX) monolithic stationary phase was prepared in 75 microm id capillaries by direct in situ polymerization of sulfopropyl methacrylate and polyethylene glycol diacrylate in a ternary porogen system consisting of methanol, cyclohexanol, and water. The resulting monolith exhibited good dynamic binding capacity, fast kinetic adsorption of proteins, and high permeability. The monolith had a dynamic binding capacity of approximately 52 mg/mL of column volume for lysozyme and cytochrome C. The monolith was evaluated for SCX capillary LC of synthetic peptides, natural peptides, and protein standards. Fast separation of proteins was achieved in less than 4 min. The average peak capacity for peptides was 28 using a relatively steep gradient when hydrophobic interactions were suppressed with 40% acetonitrile.

About this research paper

What this paper is about

A strong cation-exchange (SCX) monolithic stationary phase was prepared in 75 microm id capillaries by direct in situ polymerization of sulfopropyl methacrylate and polyethylene glycol diacrylate in a ternary porogen system consisting of methanol, cyclohexanol, and water. The resulting monolith exhibited good dynamic binding capacity, fast kinetic adsorption of proteins, and high permeability. The monolith had a dynamic binding capacity of approximately 52 mg/mL of column volume for lysozyme and cytochrome C. The monolith was evaluated for SCX capillary LC of synthetic peptides, natural peptides, and protein standards. Fast separation of proteins was achieved in less than 4 min. The average peak capacity for peptides was 28 using a relatively steep gradient when hydrophobic interactions were suppressed with 40% acetonitrile.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A strong cation-exchange (SCX) monolithic stationary phase was prepared in 75 microm id capillaries by direct in situ polymerization of sulfopropyl methacrylate and polyethylene glycol diacrylate in a ternary porogen system consisting of methanol, cyclohexanol, and water. The resulting monolith exhibited good dynamic binding capacity, fast kinetic adsorption of proteins, and high permeability. The monolith had a dynamic binding capacity of approximately 52 mg/mL of column volume for lysozyme and cytochrome C. The monolith was evaluated for SCX capillary LC of synthetic peptides, natural peptides, and protein standards. Fast separation of proteins was achieved in less than 4 min. The average peak capacity for peptides was 28 using a relatively steep gradient when hydrophobic interactions were suppressed with 40% acetonitrile.

Key concepts: Monolith, Monolithic HPLC column, Chemistry, Chromatography, Methacrylate, Capillary electrochromatography, Lysozyme, Polymerization

Related papers

Back to paper searchBrowse research topicsOriginal source
Polymeric strong cation‐exchange monolithic column for capillary liquid chromatography of peptides and proteins — Research Paper | ScholarLens