2003Rapid Communications in Mass SpectrometryRequires access

Comparison of conventional and enhanced mass resolution triple‐quadrupole mass spectrometers for discovery bioanalytical applications

Xiao‐Ying Xu, J. Veals, Walter A. Korfmacher

Open publisher page 27 citations

Abstract

A new triple-quadrupole mass spectrometry (MS) system with enhanced resolution capabilities has recently become available. In order to evaluate the performance of this new instrument for drug discovery assays, both the linearity and the limit of detection were compared in the positive electrospray ionization (ESI) mode with those of a conventional triple-quadrupole instrument supplied by the same manufacturer. For these studies, spiked mouse plasma standard samples were split and assayed by each instrument, which allowed for a direct comparison of the two systems. In the unit mass resolution mode, the new mass spectrometer was found to be at least ten-fold more sensitive than the conventional instrument. The sensitivity of the new mass spectrometer under the enhanced mass resolution mode was found to be even better by another factor of two. For the test compound, the linear dynamic range was found to be 0.05-5000 ng/mL for the new instrument as compared with 2.5-5000 ng/mL for the conventional mass spectrometer.

About this research paper

What this paper is about

A new triple-quadrupole mass spectrometry (MS) system with enhanced resolution capabilities has recently become available. In order to evaluate the performance of this new instrument for drug discovery assays, both the linearity and the limit of detection were compared in the positive electrospray ionization (ESI) mode with those of a conventional triple-quadrupole instrument supplied by the same manufacturer. For these studies, spiked mouse plasma standard samples were split and assayed by each instrument, which allowed for a direct comparison of the two systems. In the unit mass resolution mode, the new mass spectrometer was found to be at least ten-fold more sensitive than the conventional instrument. The sensitivity of the new mass spectrometer under the enhanced mass resolution mode was found to be even better by another factor of two. For the test compound, the linear dynamic range was found to be 0.05-5000 ng/mL for the new instrument as compared with 2.5-5000 ng/mL for the conventional mass spectrometer.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new triple-quadrupole mass spectrometry (MS) system with enhanced resolution capabilities has recently become available. In order to evaluate the performance of this new instrument for drug discovery assays, both the linearity and the limit of detection were compared in the positive electrospray ionization (ESI) mode with those of a conventional triple-quadrupole instrument supplied by the same manufacturer. For these studies, spiked mouse plasma standard samples were split and assayed by each instrument, which allowed for a direct comparison of the two systems. In the unit mass resolution mode, the new mass spectrometer was found to be at least ten-fold more sensitive than the conventional instrument. The sensitivity of the new mass spectrometer under the enhanced mass resolution mode was found to be even better by another factor of two. For the test compound, the linear dynamic range was found to be 0.05-5000 ng/mL for the new instrument as compared with 2.5-5000 ng/mL for the conventional mass spectrometer.

Key concepts: Triple quadrupole mass spectrometer, Chemistry, Mass spectrometry, Hybrid mass spectrometer, Quadrupole mass analyzer, Resolution (logic), Analytical Chemistry (journal), Selected reaction monitoring

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of conventional and enhanced mass resolution triple‐quadrupole mass spectrometers for discovery bioanalytical applications — Research Paper | ScholarLens