1989British Journal of NeurosurgeryRequires access

A Simple System for Image Directed Stereotaxis

J. Dervin, John Miles

Open publisher page 6 citations

Abstract

A simple system for CT directed stereotaxis has been developed. This technique represents a true three-dimensional solution to the problems of CT stereotaxis and is therefore free of positional constraints relating to the orientation of the patient/stereotactic instrument/CT scan plane, but is not dependent on the relatively complicated mathematical methods required by existing techniques. The preliminary series of 17 procedures are presented, 13 of these were designed to obtain tissue diagnosis. One patient had effective stereotactic aspiration of a colloid cyst of the third ventricle. The stereotactic instrument itself is lightweight and easy to use, a wide range of target trajectories including low sites are possible. The design of this instrument would be particularly well suited for MR directed stereotaxis.

About this research paper

What this paper is about

A simple system for CT directed stereotaxis has been developed. This technique represents a true three-dimensional solution to the problems of CT stereotaxis and is therefore free of positional constraints relating to the orientation of the patient/stereotactic instrument/CT scan plane, but is not dependent on the relatively complicated mathematical methods required by existing techniques. The preliminary series of 17 procedures are presented, 13 of these were designed to obtain tissue diagnosis. One patient had effective stereotactic aspiration of a colloid cyst of the third ventricle. The stereotactic instrument itself is lightweight and easy to use, a wide range of target trajectories including low sites are possible. The design of this instrument would be particularly well suited for MR directed stereotaxis.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple system for CT directed stereotaxis has been developed. This technique represents a true three-dimensional solution to the problems of CT stereotaxis and is therefore free of positional constraints relating to the orientation of the patient/stereotactic instrument/CT scan plane, but is not dependent on the relatively complicated mathematical methods required by existing techniques. The preliminary series of 17 procedures are presented, 13 of these were designed to obtain tissue diagnosis. One patient had effective stereotactic aspiration of a colloid cyst of the third ventricle. The stereotactic instrument itself is lightweight and easy to use, a wide range of target trajectories including low sites are possible. The design of this instrument would be particularly well suited for MR directed stereotaxis.

Key concepts: Stereotaxis, Colloid cyst, Stereotaxy, Medicine, Orientation (vector space), Third ventricle, Computer science, Stereotactic surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
A Simple System for Image Directed Stereotaxis — Research Paper | ScholarLens