1995Journal of Analytical ToxicologyRequires access

Forensic Drug Testing for Opiates. VI. Urine Testing for Hydromorphone, Hydrocodone, Oxymorphone, and Oxycodone with Commercial Opiate Immunoassays and Gas Chromatography-Mass Spectrometry

Michael L. Smith, Robert Hughes, Barry Levine, Sara Dickerson, W. D. Darwin, E. J. Cone

Open publisher page 79 citations

Abstract

Opiate testing for morphine and codeine is performed routinely in forensic urine drug-testing laboratories in an effort to identify illicit opiate abusers. In addition to heroin, the 6-keto-opioids, including hydromorphone, hydrocodone, oxymorphone, and oxycodone, have high abuse liability and are self-administered by opiate abusers, but only limited information is available on detection of these compounds by current immunoassay and gas chromatographic-mass spectrometric (GC-MS) methods. In this study, single doses of hydromorphone, hydrocodone, oxymorphone, and oxycodone were administered to human subjects, and urine samples were collected before and periodically after dosing. Opiate levels were determined in a quantitative mode with four commercial immunoassays, TDx opiates (TDx), Abuscreen radioimmunoassay (ABUS), Coat-A-Count morphine in urine (CAC), and EMIT d.a.u. opiate assay (EMIT), and by GC-MS. GC-MS assay results indicated that hydromorphone, hydrocodone, oxymorphone, and oxycodone administration resulted in rapid excretion of parent drug and O-demethylated metabolites in urine. Peak concentrations occurred within 8 h after drug administration and declined below 300 ng/mL within 24-48 h. Immunoassay testing indicated that hydromorphone, hydrocodone, and oxycodone, but not oxymorphone, were detectable in urine by TDx and EMIT (300-ng/mL cutoff) for 6-24 h. ABUS detected only hydrocodone, and CAC failed to detect any of the four 6-keto-opioid analgesics. Generally, immunoassays for opiates in urine displayed substantially lower sensitivities for 6-keto-opioids compared with GC-MS. Consequently, urine samples containing low to moderate concentrations of hydromorphone, hydrocodone, oxymorphone, and oxycodone will likely go undetected when tested by conventional immunoassays.

About this research paper

What this paper is about

Opiate testing for morphine and codeine is performed routinely in forensic urine drug-testing laboratories in an effort to identify illicit opiate abusers. In addition to heroin, the 6-keto-opioids, including hydromorphone, hydrocodone, oxymorphone, and oxycodone, have high abuse liability and are self-administered by opiate abusers, but only limited information is available on detection of these compounds by current immunoassay and gas chromatographic-mass spectrometric (GC-MS) methods. In this study, single doses of hydromorphone, hydrocodone, oxymorphone, and oxycodone were administered to human subjects, and urine samples were collected before and periodically after dosing. Opiate levels were determined in a quantitative mode with four commercial immunoassays, TDx opiates (TDx), Abuscreen radioimmunoassay (ABUS), Coat-A-Count morphine in urine (CAC), and EMIT d.a.u. opiate assay (EMIT), and by GC-MS. GC-MS assay results indicated that hydromorphone, hydrocodone, oxymorphone, and oxycodone administration resulted in rapid excretion of parent drug and O-demethylated metabolites in urine. Peak concentrations occurred within 8 h after drug administration and declined below 300 ng/mL within 24-48 h. Immunoassay testing indicated that hydromorphone, hydrocodone, and oxycodone, but not oxymorphone, were detectable in urine by TDx and EMIT (300-ng/mL cutoff) for 6-24 h. ABUS detected only hydrocodone, and CAC failed to detect any of the four 6-keto-opioid analgesics. Generally, immunoassays for opiates in urine displayed substantially lower sensitivities for 6-keto-opioids compared with GC-MS. Consequently, urine samples containing low to moderate concentrations of hydromorphone, hydrocodone, oxymorphone, and oxycodone will likely go undetected when tested by conventional immunoassays.

Why it matters

OpenAlex reports 79 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Opiate testing for morphine and codeine is performed routinely in forensic urine drug-testing laboratories in an effort to identify illicit opiate abusers. In addition to heroin, the 6-keto-opioids, including hydromorphone, hydrocodone, oxymorphone, and oxycodone, have high abuse liability and are self-administered by opiate abusers, but only limited information is available on detection of these compounds by current immunoassay and gas chromatographic-mass spectrometric (GC-MS) methods. In this study, single doses of hydromorphone, hydrocodone, oxymorphone, and oxycodone were administered to human subjects, and urine samples were collected before and periodically after dosing. Opiate levels were determined in a quantitative mode with four commercial immunoassays, TDx opiates (TDx), Abuscreen radioimmunoassay (ABUS), Coat-A-Count morphine in urine (CAC), and EMIT d.a.u. opiate assay (EMIT), and by GC-MS. GC-MS assay results indicated that hydromorphone, hydrocodone, oxymorphone, and oxycodone administration resulted in rapid excretion of parent drug and O-demethylated metabolites in urine. Peak concentrations occurred within 8 h after drug administration and declined below 300 ng/mL within 24-48 h. Immunoassay testing indicated that hydromorphone, hydrocodone, and oxycodone, but not oxymorphone, were detectable in urine by TDx and EMIT (300-ng/mL cutoff) for 6-24 h. ABUS detected only hydrocodone, and CAC failed to detect any of the four 6-keto-opioid analgesics. Generally, immunoassays for opiates in urine displayed substantially lower sensitivities for 6-keto-opioids compared with GC-MS. Consequently, urine samples containing low to moderate concentrations of hydromorphone, hydrocodone, oxymorphone, and oxycodone will likely go undetected when tested by conventional immunoassays.

Key concepts: Hydromorphone, Hydrocodone, Oxymorphone, Oxycodone, Urine, Codeine, Opiate, Morphine

Related papers

Back to paper searchBrowse research topicsOriginal source
Forensic Drug Testing for Opiates. VI. Urine Testing for Hydromorphone, Hydrocodone, Oxymorphone, and Oxycodone with Commercial Opiate Immunoassays and Gas Chromatography-Mass Spectrometry — Research Paper | ScholarLens