2003The Journal of the Acoustical Society of AmericaRequires access

Ear-canal acoustic admittance and reflectance measurements in human neonates. II. Predictions of middle-ear dysfunction and sensorineural hearing loss

Douglas H. Keefe, Michael P. Gorga, Stephen T. Neely, Fei Zhao, Betty R. Vohr

Open publisher page 57 citations

Abstract

This report describes relationships between middle-ear measurements of acoustic admittance and energy reflectance (YR) and measurements of hearing status using visual reinforcement audiometry in a neonatal hearing-screening population. Analyses were performed on 2638 ears in which combined measurements were obtained [Norton et al., Ear Hear. 21, 348-356 (2000)]. The measurements included distortion-product otoacoustic emissions (DPOAE), transient evoked otoacoustic emissions (TEOAE), and auditory brainstem responses (ABR). Models to predict hearing status using DPOAEs, TEOAEs, or ABRs were each improved by the addition of the YR factors as interactions, in which factors were calculated using factor loadings from Keefe et al. [J. Acoust. Soc. Am. 113, 389-406 (2003)]. This result suggests that information on middle-ear status improves the ability to predict hearing status. The YR factors were used to construct a middle-ear dysfunction test on 1027 normal-hearing ears in which DPOAE and TEOAE responses were either both present or both absent, the latter condition being viewed as indicative of middle-ear dysfunction. The middle-ear dysfunction test classified these ears with a nonparametric area (A) under the relative operating characteristic curve of A = 0.86, and classified normal-hearing ears that failed two-stage hearing-screening tests with areas A = 0.84 for DPOAE/ABR, and A = 0.81 for TEOAE/ABR tests. The middle-ear dysfunction test adequately generalized to a new sample population (A = 0.82).

About this research paper

What this paper is about

This report describes relationships between middle-ear measurements of acoustic admittance and energy reflectance (YR) and measurements of hearing status using visual reinforcement audiometry in a neonatal hearing-screening population. Analyses were performed on 2638 ears in which combined measurements were obtained [Norton et al., Ear Hear. 21, 348-356 (2000)]. The measurements included distortion-product otoacoustic emissions (DPOAE), transient evoked otoacoustic emissions (TEOAE), and auditory brainstem responses (ABR). Models to predict hearing status using DPOAEs, TEOAEs, or ABRs were each improved by the addition of the YR factors as interactions, in which factors were calculated using factor loadings from Keefe et al. [J. Acoust. Soc. Am. 113, 389-406 (2003)]. This result suggests that information on middle-ear status improves the ability to predict hearing status. The YR factors were used to construct a middle-ear dysfunction test on 1027 normal-hearing ears in which DPOAE and TEOAE responses were either both present or both absent, the latter condition being viewed as indicative of middle-ear dysfunction. The middle-ear dysfunction test classified these ears with a nonparametric area (A) under the relative operating characteristic curve of A = 0.86, and classified normal-hearing ears that failed two-stage hearing-screening tests with areas A = 0.84 for DPOAE/ABR, and A = 0.81 for TEOAE/ABR tests. The middle-ear dysfunction test adequately generalized to a new sample population (A = 0.82).

Why it matters

OpenAlex reports 57 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This report describes relationships between middle-ear measurements of acoustic admittance and energy reflectance (YR) and measurements of hearing status using visual reinforcement audiometry in a neonatal hearing-screening population. Analyses were performed on 2638 ears in which combined measurements were obtained [Norton et al., Ear Hear. 21, 348-356 (2000)]. The measurements included distortion-product otoacoustic emissions (DPOAE), transient evoked otoacoustic emissions (TEOAE), and auditory brainstem responses (ABR). Models to predict hearing status using DPOAEs, TEOAEs, or ABRs were each improved by the addition of the YR factors as interactions, in which factors were calculated using factor loadings from Keefe et al. [J. Acoust. Soc. Am. 113, 389-406 (2003)]. This result suggests that information on middle-ear status improves the ability to predict hearing status. The YR factors were used to construct a middle-ear dysfunction test on 1027 normal-hearing ears in which DPOAE and TEOAE responses were either both present or both absent, the latter condition being viewed as indicative of middle-ear dysfunction. The middle-ear dysfunction test classified these ears with a nonparametric area (A) under the relative operating characteristic curve of A = 0.86, and classified normal-hearing ears that failed two-stage hearing-screening tests with areas A = 0.84 for DPOAE/ABR, and A = 0.81 for TEOAE/ABR tests. The middle-ear dysfunction test adequately generalized to a new sample population (A = 0.82).

Key concepts: Audiology, Otoacoustic emission, Middle ear, Medicine, Audiometry, Ear canal, Population, Sensorineural hearing loss

Related papers

Back to paper searchBrowse research topicsOriginal source
Ear-canal acoustic admittance and reflectance measurements in human neonates. II. Predictions of middle-ear dysfunction and sensorineural hearing loss — Research Paper | ScholarLens