1998•RadiologyRequires access

Diaphragmatic and cardiac motion during suspended breathing: preliminary experience and implications for breath-hold MR imaging.

Agnes E. Holland, James W. Goldfarb, Robert R. Edelman

Open publisher page 201 citations

Abstract

PURPOSE: To investigate and quantify motion of the diaphragm and heart during suspended breathing at end inspiration and end expiration. MATERIALS AND METHODS: In 10 healthy adult volunteers, line scanning was performed to monitor the position of the diaphragm during a breath hold at end inspiration and end expiration, with a spatial and temporal resolution of 0.25 mm and 200 msec, respectively. Electrocardiographically gated, turbo fast low-angle shot (FLASH) magnetic resonance (MR) imaging was performed to monitor movement of the diaphragm and heart. RESULTS: During a breath hold, the diaphragm moved upward. At end expiration, the velocity of the diaphragm during suspended breathing was constant (mean, 0.15 mm/sec). At end inspiration, motion of the diaphragm during suspended breathing was more complex (range, 0.1-7.9 mm/sec). During a 20-second breath hold, mean displacement of the diaphragm was 25% of that during normal breathing. FLASH MR imaging revealed variations in the position of the heart during a breath hold. During suspended respiration, the heart did not return to the same position on consecutive heartbeats and, consequently, the margins of the heart typically moved inward. CONCLUSION: Breath holding does not eliminate motion of the diaphragm. Changes in the motion of the diaphragm and transthoracic pressure during a breath hold result in complex movement of the heart and may cause blurring during breath-hold MR imaging.

About this research paper

What this paper is about

PURPOSE: To investigate and quantify motion of the diaphragm and heart during suspended breathing at end inspiration and end expiration. MATERIALS AND METHODS: In 10 healthy adult volunteers, line scanning was performed to monitor the position of the diaphragm during a breath hold at end inspiration and end expiration, with a spatial and temporal resolution of 0.25 mm and 200 msec, respectively. Electrocardiographically gated, turbo fast low-angle shot (FLASH) magnetic resonance (MR) imaging was performed to monitor movement of the diaphragm and heart. RESULTS: During a breath hold, the diaphragm moved upward. At end expiration, the velocity of the diaphragm during suspended breathing was constant (mean, 0.15 mm/sec). At end inspiration, motion of the diaphragm during suspended breathing was more complex (range, 0.1-7.9 mm/sec). During a 20-second breath hold, mean displacement of the diaphragm was 25% of that during normal breathing. FLASH MR imaging revealed variations in the position of the heart during a breath hold. During suspended respiration, the heart did not return to the same position on consecutive heartbeats and, consequently, the margins of the heart typically moved inward. CONCLUSION: Breath holding does not eliminate motion of the diaphragm. Changes in the motion of the diaphragm and transthoracic pressure during a breath hold result in complex movement of the heart and may cause blurring during breath-hold MR imaging.

Why it matters

OpenAlex reports 201 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate and quantify motion of the diaphragm and heart during suspended breathing at end inspiration and end expiration. MATERIALS AND METHODS: In 10 healthy adult volunteers, line scanning was performed to monitor the position of the diaphragm during a breath hold at end inspiration and end expiration, with a spatial and temporal resolution of 0.25 mm and 200 msec, respectively. Electrocardiographically gated, turbo fast low-angle shot (FLASH) magnetic resonance (MR) imaging was performed to monitor movement of the diaphragm and heart. RESULTS: During a breath hold, the diaphragm moved upward. At end expiration, the velocity of the diaphragm during suspended breathing was constant (mean, 0.15 mm/sec). At end inspiration, motion of the diaphragm during suspended breathing was more complex (range, 0.1-7.9 mm/sec). During a 20-second breath hold, mean displacement of the diaphragm was 25% of that during normal breathing. FLASH MR imaging revealed variations in the position of the heart during a breath hold. During suspended respiration, the heart did not return to the same position on consecutive heartbeats and, consequently, the margins of the heart typically moved inward. CONCLUSION: Breath holding does not eliminate motion of the diaphragm. Changes in the motion of the diaphragm and transthoracic pressure during a breath hold result in complex movement of the heart and may cause blurring during breath-hold MR imaging.

Key concepts: Diaphragm (acoustics), Medicine, Breathing, Expiration, Diaphragmatic breathing, Magnetic resonance imaging, Nuclear medicine, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Diaphragmatic and cardiac motion during suspended breathing: preliminary experience and implications for breath-hold MR imaging. — Research Paper | ScholarLens