2001Analytical ChemistryRequires access

Generating Multiply Charged Protein Ions by Ultrasonic Nebulization/Multiple Channel-Electrospray Ionization Mass Spectrometry

Jentaie Shiea, D. Y. Chang, Chia‐Hsin Lin, Shiuh‐Jen Jiang

Open publisher page 61 citations

Abstract

An ultrasonic nebulization/multiple channel electrospray ionization (USN/MC-ES) source, which generates multiply charged peptides and proteins ions, was developed. The source is an ultrasonic nebulizer that is connected to a multiple channel electrospray ionization source. Aerosols were formed by ultrasonically nebulizing the sample solution. The aerosols were then purged into the central channel of a seven-channel ES source via nitrogen gas. A methanol solution that contained 1% trifluroacetic acid was electrosprayed through the outlying six electrosprayers. Detection of multiply charged peptide and protein ions indicated that electrospray was generated from the charged droplet containing analyte. The sample aerosol appeared to fuse with the charged methanol droplet in the air. Then electrospray ionization of the analyte occurred from the newly formed droplet. The peptide and protein prepared in deionized water were detected by this USN/MC-ES-MS. By varying the electrospray solvents, the signals of certain components in the mixture were selectively suppressed.

About this research paper

What this paper is about

An ultrasonic nebulization/multiple channel electrospray ionization (USN/MC-ES) source, which generates multiply charged peptides and proteins ions, was developed. The source is an ultrasonic nebulizer that is connected to a multiple channel electrospray ionization source. Aerosols were formed by ultrasonically nebulizing the sample solution. The aerosols were then purged into the central channel of a seven-channel ES source via nitrogen gas. A methanol solution that contained 1% trifluroacetic acid was electrosprayed through the outlying six electrosprayers. Detection of multiply charged peptide and protein ions indicated that electrospray was generated from the charged droplet containing analyte. The sample aerosol appeared to fuse with the charged methanol droplet in the air. Then electrospray ionization of the analyte occurred from the newly formed droplet. The peptide and protein prepared in deionized water were detected by this USN/MC-ES-MS. By varying the electrospray solvents, the signals of certain components in the mixture were selectively suppressed.

Why it matters

OpenAlex reports 61 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ultrasonic nebulization/multiple channel electrospray ionization (USN/MC-ES) source, which generates multiply charged peptides and proteins ions, was developed. The source is an ultrasonic nebulizer that is connected to a multiple channel electrospray ionization source. Aerosols were formed by ultrasonically nebulizing the sample solution. The aerosols were then purged into the central channel of a seven-channel ES source via nitrogen gas. A methanol solution that contained 1% trifluroacetic acid was electrosprayed through the outlying six electrosprayers. Detection of multiply charged peptide and protein ions indicated that electrospray was generated from the charged droplet containing analyte. The sample aerosol appeared to fuse with the charged methanol droplet in the air. Then electrospray ionization of the analyte occurred from the newly formed droplet. The peptide and protein prepared in deionized water were detected by this USN/MC-ES-MS. By varying the electrospray solvents, the signals of certain components in the mixture were selectively suppressed.

Key concepts: Chemistry, Electrospray ionization, Extractive electrospray ionization, Electrospray, Nebulizer, Ionization, Mass spectrometry, Ambient ionization

Related papers

Back to paper searchBrowse research topicsOriginal source
Generating Multiply Charged Protein Ions by Ultrasonic Nebulization/Multiple Channel-Electrospray Ionization Mass Spectrometry — Research Paper | ScholarLens