The Usefulness of Calculated Attenuation Correction in the Evaluation of Metallic Artifacts on Brain PET/CT Imaging

Samuel E. Almodóvar, Sharon L. White, Homayoun Modarresifar, Buddhiwardhan Ojha

Open publisher page 2 citations

Abstract

A known limitation of CT-based attenuation correction (CTAC) is the creation of artifacts that mimic increased FDG uptake in the location of metallic prostheses. Calculated attenuation correction (CAC) uses a constant value for the attenuation coefficient of brain tissue at 511 keV and corrects the reconstructed data for attenuation effects. Comparison of CTAC and NAC PET images should always be the first step when evaluating possible metallic artifacts on CTAC PET brain images. If the etiology responsible for the increased FDG uptake remains unclear, reprocessing using CAC is an additional useful tool to differentiate between artifactual and true FDG uptake.

About this research paper

What this paper is about

A known limitation of CT-based attenuation correction (CTAC) is the creation of artifacts that mimic increased FDG uptake in the location of metallic prostheses. Calculated attenuation correction (CAC) uses a constant value for the attenuation coefficient of brain tissue at 511 keV and corrects the reconstructed data for attenuation effects. Comparison of CTAC and NAC PET images should always be the first step when evaluating possible metallic artifacts on CTAC PET brain images. If the etiology responsible for the increased FDG uptake remains unclear, reprocessing using CAC is an additional useful tool to differentiate between artifactual and true FDG uptake.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A known limitation of CT-based attenuation correction (CTAC) is the creation of artifacts that mimic increased FDG uptake in the location of metallic prostheses. Calculated attenuation correction (CAC) uses a constant value for the attenuation coefficient of brain tissue at 511 keV and corrects the reconstructed data for attenuation effects. Comparison of CTAC and NAC PET images should always be the first step when evaluating possible metallic artifacts on CTAC PET brain images. If the etiology responsible for the increased FDG uptake remains unclear, reprocessing using CAC is an additional useful tool to differentiate between artifactual and true FDG uptake.

Key concepts: Correction for attenuation, Attenuation, Medicine, Nuclear medicine, Attenuation coefficient, Positron emission tomography, Radiology, Biomedical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
The Usefulness of Calculated Attenuation Correction in the Evaluation of Metallic Artifacts on Brain PET/CT Imaging — Research Paper | ScholarLens