2000Radiochimica ActaRequires access

Effects of pH and uranium concentration on the removal of uranium from drinking water by ion exchange

Kaisa Vaaramaa, Satu Pulli, Jukka Lehto

Open publisher page 36 citations

Abstract

Effects of pH in the range of 5 to 8 and uranium concentration in the range of 0.02 mg/l to 25 mg/l on the removal of uranium with a strong base anion exchange resin (SBA) and a chelating aminophosphonate resin were studied. The results of the batch and column mode experiments clearly showed that the aminophosphonate resin was an efficient exchanger for the removal of uranium at pH values close to 5 and the SBA resin at higher pH values. In the column experiments, where altogether 2000 bed volumes of drinking water simulant were processed with these exchangers, the uptake of uranium was as high as 99.8% by the aminophosphonate resin at pH 5 and 99.7% by the SBA resin at pH 8.

About this research paper

What this paper is about

Effects of pH in the range of 5 to 8 and uranium concentration in the range of 0.02 mg/l to 25 mg/l on the removal of uranium with a strong base anion exchange resin (SBA) and a chelating aminophosphonate resin were studied. The results of the batch and column mode experiments clearly showed that the aminophosphonate resin was an efficient exchanger for the removal of uranium at pH values close to 5 and the SBA resin at higher pH values. In the column experiments, where altogether 2000 bed volumes of drinking water simulant were processed with these exchangers, the uptake of uranium was as high as 99.8% by the aminophosphonate resin at pH 5 and 99.7% by the SBA resin at pH 8.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Effects of pH in the range of 5 to 8 and uranium concentration in the range of 0.02 mg/l to 25 mg/l on the removal of uranium with a strong base anion exchange resin (SBA) and a chelating aminophosphonate resin were studied. The results of the batch and column mode experiments clearly showed that the aminophosphonate resin was an efficient exchanger for the removal of uranium at pH values close to 5 and the SBA resin at higher pH values. In the column experiments, where altogether 2000 bed volumes of drinking water simulant were processed with these exchangers, the uptake of uranium was as high as 99.8% by the aminophosphonate resin at pH 5 and 99.7% by the SBA resin at pH 8.

Key concepts: Uranium, Chemistry, Ion-exchange resin, Ion exchange, Nuclear chemistry, Chelating resin, Chelation, Radiochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of pH and uranium concentration on the removal of uranium from drinking water by ion exchange — Research Paper | ScholarLens