Comparison of a new video‐optical intubation stylet versus the conventional malleable stylet in simulated difficult tracheal intubation
Péter Bíró, M. Weiss, Andri Gerber, Th. Pasch
Abstract
Péter Bíró, M. Weiss, Andri Gerber, Th. Pasch
Abstract
Handling and efficacy of a new video-optical intubation stylet were assessed in a simulated difficult tracheal intubation setting and compared with a conventional malleable stylet. Forty-five anaesthetists performed 10 tracheal intubations using both techniques. Laryngoscopy was performed by the observer, who created a grade 3 view according the classification by Cormack and Lehane. The time taken to place the tracheal tube and the final tracheal tube positions were documented. Mean (SD) intubation time for the video-optical stylet was 20.4 (7.7) s and for the malleable stylet 10.2 (3.3) s (p<0.01). With the video-optical stylet the trachea was correctly intubated in all 225 attempts; with the malleable stylet 44 (19.6%) oesophageal and 44 (19.6%) endobronchial intubations occurred (p<0.01). The video-optical intubation stylet enabled us to recognise inappropriate tracheal tube positions and to correct them immediately. This equipment can be considered a reliable and effective tool for management of the difficult airway.
OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Handling and efficacy of a new video-optical intubation stylet were assessed in a simulated difficult tracheal intubation setting and compared with a conventional malleable stylet. Forty-five anaesthetists performed 10 tracheal intubations using both techniques. Laryngoscopy was performed by the observer, who created a grade 3 view according the classification by Cormack and Lehane. The time taken to place the tracheal tube and the final tracheal tube positions were documented. Mean (SD) intubation time for the video-optical stylet was 20.4 (7.7) s and for the malleable stylet 10.2 (3.3) s (p<0.01). With the video-optical stylet the trachea was correctly intubated in all 225 attempts; with the malleable stylet 44 (19.6%) oesophageal and 44 (19.6%) endobronchial intubations occurred (p<0.01). The video-optical intubation stylet enabled us to recognise inappropriate tracheal tube positions and to correct them immediately. This equipment can be considered a reliable and effective tool for management of the difficult airway.
Key concepts: Stylet, Intubation, Medicine, Tracheal intubation, Laryngoscopy, Tracheal tube, Airway, Anesthesia