2007Cancer Biotherapy and RadiopharmaceuticalsRequires access

A Quality-Control Method for SPECT-Based Dosimetry in Targeted Radionuclide Therapy

Jonathan Gear, Elizabeth Charles-Edwards, Mike Partridge, Glenn Flux

Open publisher page 16 citations

Abstract

Dosimetry for targeted radionuclide therapy is necessary for treatment planning and radiation protection. Currently, there are no standard methods either for performing dosimetry or to evaluate the uncertainties inherent in the dosimetric calculations. In this paper, we present an experimental method using polymer gel dosimeters, whereby absorbed-dose distributions resulting from nonuniform distributions of activity may be determined directly from T(2) magnetic resonance imaging (MRI) as well as from scintigraphic images. A phantom containing a nonuniform distribution of I-131 was prepared by mixing 58 MBq of activity within the gel as it was solidifying. The resulting absorbed-dose distribution was determined directly from the MRI and from sequential single-photon emission computed tomography (SPECT) images using the Medical Internal Radiation Dose (MIRD) schema. The MRI data were quantified using 12 calibration vials uniformly irradiated by 0-12 MBq of I-131. The agreement between the two absorbed-dose maps was verified by convolving the MRI-based absorbed-dose map with the SPECT system point spread function, which gave a correlation coefficient of 0.96. It was seen that the absorbed-dose distribution, as imaged by the MRI, was misrepresented by the SPECT owing to its relatively poor spatial resolution, which included a shift of the voxel containing the maximum absorbed dose. This technique could provide an independent benchmark for assessing patient-specific dosimetry and, therefore, could be used as a basis for quality control for dosimetry.

About this research paper

What this paper is about

Dosimetry for targeted radionuclide therapy is necessary for treatment planning and radiation protection. Currently, there are no standard methods either for performing dosimetry or to evaluate the uncertainties inherent in the dosimetric calculations. In this paper, we present an experimental method using polymer gel dosimeters, whereby absorbed-dose distributions resulting from nonuniform distributions of activity may be determined directly from T(2) magnetic resonance imaging (MRI) as well as from scintigraphic images. A phantom containing a nonuniform distribution of I-131 was prepared by mixing 58 MBq of activity within the gel as it was solidifying. The resulting absorbed-dose distribution was determined directly from the MRI and from sequential single-photon emission computed tomography (SPECT) images using the Medical Internal Radiation Dose (MIRD) schema. The MRI data were quantified using 12 calibration vials uniformly irradiated by 0-12 MBq of I-131. The agreement between the two absorbed-dose maps was verified by convolving the MRI-based absorbed-dose map with the SPECT system point spread function, which gave a correlation coefficient of 0.96. It was seen that the absorbed-dose distribution, as imaged by the MRI, was misrepresented by the SPECT owing to its relatively poor spatial resolution, which included a shift of the voxel containing the maximum absorbed dose. This technique could provide an independent benchmark for assessing patient-specific dosimetry and, therefore, could be used as a basis for quality control for dosimetry.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Dosimetry for targeted radionuclide therapy is necessary for treatment planning and radiation protection. Currently, there are no standard methods either for performing dosimetry or to evaluate the uncertainties inherent in the dosimetric calculations. In this paper, we present an experimental method using polymer gel dosimeters, whereby absorbed-dose distributions resulting from nonuniform distributions of activity may be determined directly from T(2) magnetic resonance imaging (MRI) as well as from scintigraphic images. A phantom containing a nonuniform distribution of I-131 was prepared by mixing 58 MBq of activity within the gel as it was solidifying. The resulting absorbed-dose distribution was determined directly from the MRI and from sequential single-photon emission computed tomography (SPECT) images using the Medical Internal Radiation Dose (MIRD) schema. The MRI data were quantified using 12 calibration vials uniformly irradiated by 0-12 MBq of I-131. The agreement between the two absorbed-dose maps was verified by convolving the MRI-based absorbed-dose map with the SPECT system point spread function, which gave a correlation coefficient of 0.96. It was seen that the absorbed-dose distribution, as imaged by the MRI, was misrepresented by the SPECT owing to its relatively poor spatial resolution, which included a shift of the voxel containing the maximum absorbed dose. This technique could provide an independent benchmark for assessing patient-specific dosimetry and, therefore, could be used as a basis for quality control for dosimetry.

Key concepts: Dosimetry, Absorbed dose, Imaging phantom, Nuclear medicine, Dosimeter, Radionuclide therapy, Radiation treatment planning, Voxel

Related papers

Back to paper searchBrowse research topicsOriginal source
A Quality-Control Method for SPECT-Based Dosimetry in Targeted Radionuclide Therapy — Research Paper | ScholarLens