2013Archives of Pathology & Laboratory MedicineRequires access

Comparison Between 1-Needle Technique Versus 2-Needle Technique for Bone Marrow Aspiration and Biopsy Procedures

Alyaa Al‐Ibraheemi, Tiffany Pham, Lei Chen, Erica Syklawer, Andres Ernesto Quesada, Amer Wahed, Elena Nedelcu, Andy N. D. Nguyen

Open publisher page 11 citations

Abstract

CONTEXT: Bone marrow examination is essential for diagnosis and staging of hematologic disorders. Traditionally, the bone marrow biopsy and aspirate are obtained with 2 needles at 2 separate sites. This approach is associated with significant discomfort, procedural time, and occasionally, morbidity. Although previous observations had suggested that a single-needle technique at one site is a simpler and less-painful procedure, there had been concern that the 1-needle technique may yield a suboptimal biopsy for diagnosis. OBJECTIVE: To conduct a systematic comparison of multiple parameters of bone marrow biopsy specimens obtained by the traditional 2-needle technique versus the 1-needle technique for bone marrow collection. DESIGN: We retrospectively evaluated 20 biopsy specimens obtained by each of the 2 mentioned techniques by comparing the morphologic quality of the biopsy, biopsy length, and biopsy cellularity. RESULTS: We found that the 1-needle technique yielded an adequate biopsy for diagnosis. The measured parameters of the samples obtained by the 1-needle versus 2-needle techniques were similar. CONCLUSION: This study suggests that the 1-needle technique may be preferred for bone marrow aspirate and biopsy.

About this research paper

What this paper is about

CONTEXT: Bone marrow examination is essential for diagnosis and staging of hematologic disorders. Traditionally, the bone marrow biopsy and aspirate are obtained with 2 needles at 2 separate sites. This approach is associated with significant discomfort, procedural time, and occasionally, morbidity. Although previous observations had suggested that a single-needle technique at one site is a simpler and less-painful procedure, there had been concern that the 1-needle technique may yield a suboptimal biopsy for diagnosis. OBJECTIVE: To conduct a systematic comparison of multiple parameters of bone marrow biopsy specimens obtained by the traditional 2-needle technique versus the 1-needle technique for bone marrow collection. DESIGN: We retrospectively evaluated 20 biopsy specimens obtained by each of the 2 mentioned techniques by comparing the morphologic quality of the biopsy, biopsy length, and biopsy cellularity. RESULTS: We found that the 1-needle technique yielded an adequate biopsy for diagnosis. The measured parameters of the samples obtained by the 1-needle versus 2-needle techniques were similar. CONCLUSION: This study suggests that the 1-needle technique may be preferred for bone marrow aspirate and biopsy.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

CONTEXT: Bone marrow examination is essential for diagnosis and staging of hematologic disorders. Traditionally, the bone marrow biopsy and aspirate are obtained with 2 needles at 2 separate sites. This approach is associated with significant discomfort, procedural time, and occasionally, morbidity. Although previous observations had suggested that a single-needle technique at one site is a simpler and less-painful procedure, there had been concern that the 1-needle technique may yield a suboptimal biopsy for diagnosis. OBJECTIVE: To conduct a systematic comparison of multiple parameters of bone marrow biopsy specimens obtained by the traditional 2-needle technique versus the 1-needle technique for bone marrow collection. DESIGN: We retrospectively evaluated 20 biopsy specimens obtained by each of the 2 mentioned techniques by comparing the morphologic quality of the biopsy, biopsy length, and biopsy cellularity. RESULTS: We found that the 1-needle technique yielded an adequate biopsy for diagnosis. The measured parameters of the samples obtained by the 1-needle versus 2-needle techniques were similar. CONCLUSION: This study suggests that the 1-needle technique may be preferred for bone marrow aspirate and biopsy.

Key concepts: Biopsy, Medicine, Bone marrow, Needle biopsy, Context (archaeology), Radiology, Bone biopsy, Aspiration biopsy

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison Between 1-Needle Technique Versus 2-Needle Technique for Bone Marrow Aspiration and Biopsy Procedures — Research Paper | ScholarLens