2010Investigative Ophthalmology & Visual ScienceRequires access

Correlations between Parameters of Aqueous Humor Dynamics and the Influence of Central Corneal Thickness

Vikas Gulati, Deepta Ghate, Carl B. Camras, Carol B. Toris

Open publisher page 12 citations

Abstract

PURPOSE: The individual parameters of aqueous humor dynamics may influence each other to maintain intraocular pressure (IOP) homeostasis. Central corneal thickness (CCT) is known to be associated with onset and progression of glaucoma and can potentially influence the individual parameters of aqueous humor dynamics that maintain IOP. This study investigates the correlation between parameters of aqueous humor dynamics and the influence of CCT in healthy volunteers and compares it with the correlations seen in patients with ocular hypertension. METHODS: Aqueous humor dynamics (aqueous flow, outflow facility, and uveoscleral outflow), IOP, and pachymetry data from 94 healthy ocular normotensive (ONT) volunteers and 63 ocular hypertensive (OHT) patients was analyzed retrospectively. Linear correlations between individual aqueous humor dynamics parameters and pachymetry were evaluated using scatter plots and the Spearman correlation coefficient where appropriate. RESULTS: In both groups, a significant (P < 0.05) negative correlation was found between corneal thickness and aqueous flow (ONT, R(2) = 0.14; OHT, R(2) = 0.10) and between corneal thickness and uveoscleral outflow (ONT and OHT, R(2) = 0.10). A significant (P < 0.05) positive correlation was found between aqueous flow and outflow facility (ONT, R (2) = 0.24; OHT, R(2) = 0.10). In healthy controls, but not OHT patients, a significant (P < 0.001) positive correlation was found between aqueous flow and uveoscleral outflow (R(2) = 0.15). CONCLUSIONS: Thicker corneas may be associated with lower aqueous production and lower uveoscleral outflow. The interplay between parameters of aqueous humor dynamics suggests possible autoregulatory mechanisms in the eye. OHT may differ from ONT subjects in their inability to increase the uveoscleral outflow with increases in aqueous inflow.

About this research paper

What this paper is about

PURPOSE: The individual parameters of aqueous humor dynamics may influence each other to maintain intraocular pressure (IOP) homeostasis. Central corneal thickness (CCT) is known to be associated with onset and progression of glaucoma and can potentially influence the individual parameters of aqueous humor dynamics that maintain IOP. This study investigates the correlation between parameters of aqueous humor dynamics and the influence of CCT in healthy volunteers and compares it with the correlations seen in patients with ocular hypertension. METHODS: Aqueous humor dynamics (aqueous flow, outflow facility, and uveoscleral outflow), IOP, and pachymetry data from 94 healthy ocular normotensive (ONT) volunteers and 63 ocular hypertensive (OHT) patients was analyzed retrospectively. Linear correlations between individual aqueous humor dynamics parameters and pachymetry were evaluated using scatter plots and the Spearman correlation coefficient where appropriate. RESULTS: In both groups, a significant (P < 0.05) negative correlation was found between corneal thickness and aqueous flow (ONT, R(2) = 0.14; OHT, R(2) = 0.10) and between corneal thickness and uveoscleral outflow (ONT and OHT, R(2) = 0.10). A significant (P < 0.05) positive correlation was found between aqueous flow and outflow facility (ONT, R (2) = 0.24; OHT, R(2) = 0.10). In healthy controls, but not OHT patients, a significant (P < 0.001) positive correlation was found between aqueous flow and uveoscleral outflow (R(2) = 0.15). CONCLUSIONS: Thicker corneas may be associated with lower aqueous production and lower uveoscleral outflow. The interplay between parameters of aqueous humor dynamics suggests possible autoregulatory mechanisms in the eye. OHT may differ from ONT subjects in their inability to increase the uveoscleral outflow with increases in aqueous inflow.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The individual parameters of aqueous humor dynamics may influence each other to maintain intraocular pressure (IOP) homeostasis. Central corneal thickness (CCT) is known to be associated with onset and progression of glaucoma and can potentially influence the individual parameters of aqueous humor dynamics that maintain IOP. This study investigates the correlation between parameters of aqueous humor dynamics and the influence of CCT in healthy volunteers and compares it with the correlations seen in patients with ocular hypertension. METHODS: Aqueous humor dynamics (aqueous flow, outflow facility, and uveoscleral outflow), IOP, and pachymetry data from 94 healthy ocular normotensive (ONT) volunteers and 63 ocular hypertensive (OHT) patients was analyzed retrospectively. Linear correlations between individual aqueous humor dynamics parameters and pachymetry were evaluated using scatter plots and the Spearman correlation coefficient where appropriate. RESULTS: In both groups, a significant (P < 0.05) negative correlation was found between corneal thickness and aqueous flow (ONT, R(2) = 0.14; OHT, R(2) = 0.10) and between corneal thickness and uveoscleral outflow (ONT and OHT, R(2) = 0.10). A significant (P < 0.05) positive correlation was found between aqueous flow and outflow facility (ONT, R (2) = 0.24; OHT, R(2) = 0.10). In healthy controls, but not OHT patients, a significant (P < 0.001) positive correlation was found between aqueous flow and uveoscleral outflow (R(2) = 0.15). CONCLUSIONS: Thicker corneas may be associated with lower aqueous production and lower uveoscleral outflow. The interplay between parameters of aqueous humor dynamics suggests possible autoregulatory mechanisms in the eye. OHT may differ from ONT subjects in their inability to increase the uveoscleral outflow with increases in aqueous inflow.

Key concepts: Aqueous humor, Ophthalmology, Outflow, Intraocular pressure, Ocular hypertension, Glaucoma, Dynamics (music), Positive correlation

Related papers

Back to paper searchBrowse research topicsOriginal source
Correlations between Parameters of Aqueous Humor Dynamics and the Influence of Central Corneal Thickness — Research Paper | ScholarLens