Many kinds of dampers are invented to reduce the dynamic responses due to earthquake or strong wind. Viscoelastic damper is a kind of commonly used passive control device for vibration mitigation of structures. Its energy dissipation characteristics are affected by environmental temperature and excitation frequency. In order to describe the complex characteristics of viscoelastic dampers changing with temperature and frequency, a new model — the equivalent standard solid model, which is based on the standard linear solid model and temperature-frequency equivalent theory, is proposed. The comparison results between experimental and numerical data of viscoelastic dampers show that the equivalent standard solid model can precisely describe energy dissipation behavior of viscoelastic dampers under different temperatures and frequencies. At the same time, 52 viscoelastic dampers are applied for seismic retrofit design on Xi’an Petrol Hotel, and the finite analysis for structures with and without dampers are carried out under frequent-earthquake and infrequent-earthquake excitations. The dynamic responses of structures with and without dampers are compared. Analytical results show that viscoelastic dampers can reduce the earthquake responses effectively, and they are high-performance energy dissipation devices.

About this research paper

What this paper is about

Many kinds of dampers are invented to reduce the dynamic responses due to earthquake or strong wind. Viscoelastic damper is a kind of commonly used passive control device for vibration mitigation of structures. Its energy dissipation characteristics are affected by environmental temperature and excitation frequency. In order to describe the complex characteristics of viscoelastic dampers changing with temperature and frequency, a new model — the equivalent standard solid model, which is based on the standard linear solid model and temperature-frequency equivalent theory, is proposed. The comparison results between experimental and numerical data of viscoelastic dampers show that the equivalent standard solid model can precisely describe energy dissipation behavior of viscoelastic dampers under different temperatures and frequencies. At the same time, 52 viscoelastic dampers are applied for seismic retrofit design on Xi’an Petrol Hotel, and the finite analysis for structures with and without dampers are carried out under frequent-earthquake and infrequent-earthquake excitations. The dynamic responses of structures with and without dampers are compared. Analytical results show that viscoelastic dampers can reduce the earthquake responses effectively, and they are high-performance energy dissipation devices.

Why it matters

OpenAlex reports 136 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Many kinds of dampers are invented to reduce the dynamic responses due to earthquake or strong wind. Viscoelastic damper is a kind of commonly used passive control device for vibration mitigation of structures. Its energy dissipation characteristics are affected by environmental temperature and excitation frequency. In order to describe the complex characteristics of viscoelastic dampers changing with temperature and frequency, a new model — the equivalent standard solid model, which is based on the standard linear solid model and temperature-frequency equivalent theory, is proposed. The comparison results between experimental and numerical data of viscoelastic dampers show that the equivalent standard solid model can precisely describe energy dissipation behavior of viscoelastic dampers under different temperatures and frequencies. At the same time, 52 viscoelastic dampers are applied for seismic retrofit design on Xi’an Petrol Hotel, and the finite analysis for structures with and without dampers are carried out under frequent-earthquake and infrequent-earthquake excitations. The dynamic responses of structures with and without dampers are compared. Analytical results show that viscoelastic dampers can reduce the earthquake responses effectively, and they are high-performance energy dissipation devices.

Key concepts: Damper, Dissipation, Viscoelasticity, Structural engineering, Vibration, Vibration control, Standard linear solid model, Engineering