Comparison of real-time intraocular pressure during laser in situ keratomileusis and epithelial laser in situ keratomileusis in porcine eyes
José Luis Hernández‐Verdejo, Laura de Benito-Llopis, Miguel A. Teus
Abstract
José Luis Hernández‐Verdejo, Laura de Benito-Llopis, Miguel A. Teus
Abstract
PURPOSE: To compare real-time intraocular pressure (IOP) between laser in situ keratomileusis (LASIK) and epithelial LASIK (epi-LASIK) in porcine eyes during flap creation using a microkeratome or an epikeratome, respectively. SETTING: Vissum Madrid, Madrid, Spain. METHODS: In this prospective study, a Moria microkeratome was used in 1 eye (LASIK group) and an Epi-K epikeratome in the other eye (epi-LASIK group) to create a lamellar corneal flap and an epithelial flap, respectively, in freshly enucleated porcine eyes. The IOP changes during the procedures were recorded by direct cannulation using a reusable blood pressure transducer connected to the anterior chamber. RESULTS: Each group comprised 17 eyes. In the LASIK group, the mean IOP was 113.65 mm Hg +/- 10.78 (SD) during suctioning and 112.35 +/- 11.51 mm Hg during cutting phases. The mean duration of the phases was 9.00 +/- 1.46 seconds and 6.06 +/- 1.14 seconds, respectively. In the epi-LASIK group, the mean IOP was 92.57 +/- 20.86 mm Hg during suctioning, 82.09 +/- 20 mm Hg during cutting, and 67.28 +/- 13.49 during low vacuum. The mean duration of the phases was 25.88 +/- 1.96 seconds, 33.82 +/- 2.81 seconds, and 29.71 +/- 3.29 seconds, respectively. The IOP values were significantly different between the 2 groups (all comparisons P<.05). CONCLUSION: Real-time IOP measured during suctioning and flap creation by direct cannulation of the anterior chamber in freshly enucleated porcine eyes showed a significant increase in IOP during LASIK and epi-LASIK; the increase was lower in the epi-LASIK group.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To compare real-time intraocular pressure (IOP) between laser in situ keratomileusis (LASIK) and epithelial LASIK (epi-LASIK) in porcine eyes during flap creation using a microkeratome or an epikeratome, respectively. SETTING: Vissum Madrid, Madrid, Spain. METHODS: In this prospective study, a Moria microkeratome was used in 1 eye (LASIK group) and an Epi-K epikeratome in the other eye (epi-LASIK group) to create a lamellar corneal flap and an epithelial flap, respectively, in freshly enucleated porcine eyes. The IOP changes during the procedures were recorded by direct cannulation using a reusable blood pressure transducer connected to the anterior chamber. RESULTS: Each group comprised 17 eyes. In the LASIK group, the mean IOP was 113.65 mm Hg +/- 10.78 (SD) during suctioning and 112.35 +/- 11.51 mm Hg during cutting phases. The mean duration of the phases was 9.00 +/- 1.46 seconds and 6.06 +/- 1.14 seconds, respectively. In the epi-LASIK group, the mean IOP was 92.57 +/- 20.86 mm Hg during suctioning, 82.09 +/- 20 mm Hg during cutting, and 67.28 +/- 13.49 during low vacuum. The mean duration of the phases was 25.88 +/- 1.96 seconds, 33.82 +/- 2.81 seconds, and 29.71 +/- 3.29 seconds, respectively. The IOP values were significantly different between the 2 groups (all comparisons P<.05). CONCLUSION: Real-time IOP measured during suctioning and flap creation by direct cannulation of the anterior chamber in freshly enucleated porcine eyes showed a significant increase in IOP during LASIK and epi-LASIK; the increase was lower in the epi-LASIK group.
Key concepts: Keratomileusis, Microkeratome, LASIK, Ophthalmology, Intraocular pressure, Medicine, Cornea