The stability of electrically induced ventricular fibrillation

Mark W. Kroll, Gregory P. Walcott, Raymond E. Ideker, M. A. Graham, Hugh G Calkins, D. Lakkireddy, Richard M. Luceri, Dorin Panescu

Open publisher page 11 citations

Abstract

The first recorded heart rhythm for cardiac arrest patients can either be ventricular fibrillation (VF) which is treatable with a defibrillator, or asystole or pulseless electrical activity (PEA) which are not. The time course for the deterioration of VF to either asystole or PEA is not well understood. Knowing the time course of this deterioration may allow for improvements in emergency service delivery. In addition, this may improve the diagnosis of possible electrocutions from various electrical sources including utility power, electric fences, or electronic control devices (ECDs) such as a TASER(®) ECD. We induced VF in 6 ventilated swine by electrically maintaining rapid cardiac capture, with resulting hypotension, for 90 seconds. No circulatory assistance was provided. They were then monitored for 40 minutes via an electrode in the right ventricle. Only 2 swine remained in VF; 3 progressed to asystole; 1 progressed to PEA. These results were used in a logistic regression model. The results are then compared to published animal and human data. The median time for the deterioration of electrically induced VF in the swine was 35 minutes. At 24 minutes VF was still maintained in all of the animals. We conclude that electrically induced VF is long-lived--even in the absence of chest compressions.

About this research paper

What this paper is about

The first recorded heart rhythm for cardiac arrest patients can either be ventricular fibrillation (VF) which is treatable with a defibrillator, or asystole or pulseless electrical activity (PEA) which are not. The time course for the deterioration of VF to either asystole or PEA is not well understood. Knowing the time course of this deterioration may allow for improvements in emergency service delivery. In addition, this may improve the diagnosis of possible electrocutions from various electrical sources including utility power, electric fences, or electronic control devices (ECDs) such as a TASER(®) ECD. We induced VF in 6 ventilated swine by electrically maintaining rapid cardiac capture, with resulting hypotension, for 90 seconds. No circulatory assistance was provided. They were then monitored for 40 minutes via an electrode in the right ventricle. Only 2 swine remained in VF; 3 progressed to asystole; 1 progressed to PEA. These results were used in a logistic regression model. The results are then compared to published animal and human data. The median time for the deterioration of electrically induced VF in the swine was 35 minutes. At 24 minutes VF was still maintained in all of the animals. We conclude that electrically induced VF is long-lived--even in the absence of chest compressions.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The first recorded heart rhythm for cardiac arrest patients can either be ventricular fibrillation (VF) which is treatable with a defibrillator, or asystole or pulseless electrical activity (PEA) which are not. The time course for the deterioration of VF to either asystole or PEA is not well understood. Knowing the time course of this deterioration may allow for improvements in emergency service delivery. In addition, this may improve the diagnosis of possible electrocutions from various electrical sources including utility power, electric fences, or electronic control devices (ECDs) such as a TASER(®) ECD. We induced VF in 6 ventilated swine by electrically maintaining rapid cardiac capture, with resulting hypotension, for 90 seconds. No circulatory assistance was provided. They were then monitored for 40 minutes via an electrode in the right ventricle. Only 2 swine remained in VF; 3 progressed to asystole; 1 progressed to PEA. These results were used in a logistic regression model. The results are then compared to published animal and human data. The median time for the deterioration of electrically induced VF in the swine was 35 minutes. At 24 minutes VF was still maintained in all of the animals. We conclude that electrically induced VF is long-lived--even in the absence of chest compressions.

Key concepts: Asystole, Ventricular fibrillation, Pulseless electrical activity, Internal medicine, Medicine, Cardiology, Ventricle, Defibrillation