2008•Cytometry Part B Clinical CytometryRequires access

A new case of acquired Glanzmann's thrombasthenia: Diagnostic value of flow cytometry

Silvia Giannini, Anna Maria Mezzasoma, Giuseppe Guglielmini, Roberta Elisa Rossi, Emanuela Falcinelli, Paolo Gresele

Open publisher page 40 citations

Abstract

BACKGROUND: Acquired Glanzmann's thrombasthenia (aGT) is a rare hemorrhagic disorder caused by autoantibodies, alloantibodies, or paraproteins directed against platelet GPIIb/IIIa. Its diagnosis requires several laboratory assays and mixing tests, which are complex and time consuming. We describe here a new case of aGT and compare different tests for the detection of GPIIb/IIIa-blocking autoantibodies. METHODS: A previously healthy 27-year-old male developed severe mucocutaneous bleeding, despite a normal platelet count, associated with non Hodgkin lymphoma. RESULTS: Blood clotting tests were normal. Bleeding time and PFA-100 were unmeasurable. Platelet aggregation was absent in response to all agonists except ristocetin. Platelet adhesion to collagen at high shear was impaired. Platelet granular content and release was normal. Flow cytometry showed normal binding of some anti-GPIIb/IIIa antibodies (SZ21 and SAP), and decreased binding of others (P2, SZ22, A2A 9/6). Binding of PAC-1, against activated GPIIb/IIIa, and of fibrinogen, was absent. In mixing tests, patient's serum inhibited aggregation, adhesion, and PAC-1 and A2A9/6 binding to control platelets. The patient's antibody, purified by affinity chromatography, recognized purified GPIIb by western blotting. Isolated patient's IgG inhibited platelet aggregation and A2A 9/6 binding by flow cytometry. CONCLUSIONS: Flow cytometry is especially useful for the diagnosis of aGT, being the only test able to characterize both the functional effect and the molecular target of the patient's autoantibody.

About this research paper

What this paper is about

BACKGROUND: Acquired Glanzmann's thrombasthenia (aGT) is a rare hemorrhagic disorder caused by autoantibodies, alloantibodies, or paraproteins directed against platelet GPIIb/IIIa. Its diagnosis requires several laboratory assays and mixing tests, which are complex and time consuming. We describe here a new case of aGT and compare different tests for the detection of GPIIb/IIIa-blocking autoantibodies. METHODS: A previously healthy 27-year-old male developed severe mucocutaneous bleeding, despite a normal platelet count, associated with non Hodgkin lymphoma. RESULTS: Blood clotting tests were normal. Bleeding time and PFA-100 were unmeasurable. Platelet aggregation was absent in response to all agonists except ristocetin. Platelet adhesion to collagen at high shear was impaired. Platelet granular content and release was normal. Flow cytometry showed normal binding of some anti-GPIIb/IIIa antibodies (SZ21 and SAP), and decreased binding of others (P2, SZ22, A2A 9/6). Binding of PAC-1, against activated GPIIb/IIIa, and of fibrinogen, was absent. In mixing tests, patient's serum inhibited aggregation, adhesion, and PAC-1 and A2A9/6 binding to control platelets. The patient's antibody, purified by affinity chromatography, recognized purified GPIIb by western blotting. Isolated patient's IgG inhibited platelet aggregation and A2A 9/6 binding by flow cytometry. CONCLUSIONS: Flow cytometry is especially useful for the diagnosis of aGT, being the only test able to characterize both the functional effect and the molecular target of the patient's autoantibody.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Acquired Glanzmann's thrombasthenia (aGT) is a rare hemorrhagic disorder caused by autoantibodies, alloantibodies, or paraproteins directed against platelet GPIIb/IIIa. Its diagnosis requires several laboratory assays and mixing tests, which are complex and time consuming. We describe here a new case of aGT and compare different tests for the detection of GPIIb/IIIa-blocking autoantibodies. METHODS: A previously healthy 27-year-old male developed severe mucocutaneous bleeding, despite a normal platelet count, associated with non Hodgkin lymphoma. RESULTS: Blood clotting tests were normal. Bleeding time and PFA-100 were unmeasurable. Platelet aggregation was absent in response to all agonists except ristocetin. Platelet adhesion to collagen at high shear was impaired. Platelet granular content and release was normal. Flow cytometry showed normal binding of some anti-GPIIb/IIIa antibodies (SZ21 and SAP), and decreased binding of others (P2, SZ22, A2A 9/6). Binding of PAC-1, against activated GPIIb/IIIa, and of fibrinogen, was absent. In mixing tests, patient's serum inhibited aggregation, adhesion, and PAC-1 and A2A9/6 binding to control platelets. The patient's antibody, purified by affinity chromatography, recognized purified GPIIb by western blotting. Isolated patient's IgG inhibited platelet aggregation and A2A 9/6 binding by flow cytometry. CONCLUSIONS: Flow cytometry is especially useful for the diagnosis of aGT, being the only test able to characterize both the functional effect and the molecular target of the patient's autoantibody.

Key concepts: Thrombasthenia, Platelet, Flow cytometry, Glanzmann's thrombasthenia, Autoantibody, Platelet membrane glycoprotein, Antibody, Ristocetin

Related papers

Back to paper searchBrowse research topicsOriginal source
A new case of acquired Glanzmann's thrombasthenia: Diagnostic value of flow cytometry — Research Paper | ScholarLens