1984Anesthesia & AnalgesiaRequires access

Closed Circuit Anesthesia in Infants and Children

Jos Maria Couto da Silva, Paulo Juvencio Tubino, Z Vieira, Renato Ângelo Saraiva

Open publisher page 6 citations

Abstract

A closed-system low-flow technique with enflurane, halothane, or isoflurane as the sole anesthetic was used in three groups of ten children each. Anesthesia was induced by injection into the expiratory limb of a priming standard dose of the liquid anesthetic, followed by additional doses at 15, 30, 60, and 90 sec, and 2, 3, and 4 min. Further injections following the "square root of time" sequence were used for maintenance. Volumes of anesthetics used averaged 3.7 +/- 1.1 ml for enflurane, 2.3 +/- 1.1 ml for halothane, and 3.0 +/- 0.9 ml for isoflurane. These volumes were higher than predicted on theoretical grounds, as was the frequency with which anesthetics had to be injected. Closed-system low-flow anesthesia is a practical, economical, and nonpolluting technique in pediatric patients. Complications associated with isoflurane suggest, however, that isoflurane is not as satisfactory as enflurane or halothane when using this technique in infants and children.

About this research paper

What this paper is about

A closed-system low-flow technique with enflurane, halothane, or isoflurane as the sole anesthetic was used in three groups of ten children each. Anesthesia was induced by injection into the expiratory limb of a priming standard dose of the liquid anesthetic, followed by additional doses at 15, 30, 60, and 90 sec, and 2, 3, and 4 min. Further injections following the "square root of time" sequence were used for maintenance. Volumes of anesthetics used averaged 3.7 +/- 1.1 ml for enflurane, 2.3 +/- 1.1 ml for halothane, and 3.0 +/- 0.9 ml for isoflurane. These volumes were higher than predicted on theoretical grounds, as was the frequency with which anesthetics had to be injected. Closed-system low-flow anesthesia is a practical, economical, and nonpolluting technique in pediatric patients. Complications associated with isoflurane suggest, however, that isoflurane is not as satisfactory as enflurane or halothane when using this technique in infants and children.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A closed-system low-flow technique with enflurane, halothane, or isoflurane as the sole anesthetic was used in three groups of ten children each. Anesthesia was induced by injection into the expiratory limb of a priming standard dose of the liquid anesthetic, followed by additional doses at 15, 30, 60, and 90 sec, and 2, 3, and 4 min. Further injections following the "square root of time" sequence were used for maintenance. Volumes of anesthetics used averaged 3.7 +/- 1.1 ml for enflurane, 2.3 +/- 1.1 ml for halothane, and 3.0 +/- 0.9 ml for isoflurane. These volumes were higher than predicted on theoretical grounds, as was the frequency with which anesthetics had to be injected. Closed-system low-flow anesthesia is a practical, economical, and nonpolluting technique in pediatric patients. Complications associated with isoflurane suggest, however, that isoflurane is not as satisfactory as enflurane or halothane when using this technique in infants and children.

Key concepts: Enflurane, Isoflurane, Halothane, Medicine, Anesthesia, Anesthetic, Volatile anesthetic

Related papers

Back to paper searchBrowse research topicsOriginal source
Closed Circuit Anesthesia in Infants and Children — Research Paper | ScholarLens