Predictive Model for Equivalent Ice Thickness Load on Overhead Transmission Lines Based on Measured Insulator String Deviations
Xingliang Jiang, Ze Xiang, Zhijin Zhang, Jianlin Hu, Qin Hu, Lichun Shu
Abstract
Xingliang Jiang, Ze Xiang, Zhijin Zhang, Jianlin Hu, Qin Hu, Lichun Shu
Abstract
Transmission-line icing presents a serious threat to the safe operation of power systems. Therefore, the icing condition of overhead transmission lines must be accurately calculated for online monitoring and prewarning systems. Based on the icing data obtained at Xuefeng Mountain Natural Icing Stations (XMNIS), the cross-sectional shape of glaze icing on conductors was studied, and the correction coefficient of the actual nonuniform ice was proposed to provide an accurate and convenient method for field icing measurement. In addition, by analyzing the characteristics of the tension and tilt of the insulator string at the iced tangent tower, a new mechanical calculation model considering the ice and wind loads was established. One-month field observations and experiments were conducted in XMNIS, and it is shown that the calculation results have good agreement with experiment results, which suggests that the model can be used for ice thickness calculation and online monitoring on transmission lines.
OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Transmission-line icing presents a serious threat to the safe operation of power systems. Therefore, the icing condition of overhead transmission lines must be accurately calculated for online monitoring and prewarning systems. Based on the icing data obtained at Xuefeng Mountain Natural Icing Stations (XMNIS), the cross-sectional shape of glaze icing on conductors was studied, and the correction coefficient of the actual nonuniform ice was proposed to provide an accurate and convenient method for field icing measurement. In addition, by analyzing the characteristics of the tension and tilt of the insulator string at the iced tangent tower, a new mechanical calculation model considering the ice and wind loads was established. One-month field observations and experiments were conducted in XMNIS, and it is shown that the calculation results have good agreement with experiment results, which suggests that the model can be used for ice thickness calculation and online monitoring on transmission lines.
Key concepts: Icing, Electric power transmission, Insulator (electricity), Overhead line, Transmission line, Electrical conductor, Overhead (engineering), Transmission tower