2014IEEE Transactions on Power DeliveryRequires access

Predictive Model for Equivalent Ice Thickness Load on Overhead Transmission Lines Based on Measured Insulator String Deviations

Xingliang Jiang, Ze Xiang, Zhijin Zhang, Jianlin Hu, Qin Hu, Lichun Shu

Open publisher page 71 citations

Abstract

Transmission-line icing presents a serious threat to the safe operation of power systems. Therefore, the icing condition of overhead transmission lines must be accurately calculated for online monitoring and prewarning systems. Based on the icing data obtained at Xuefeng Mountain Natural Icing Stations (XMNIS), the cross-sectional shape of glaze icing on conductors was studied, and the correction coefficient of the actual nonuniform ice was proposed to provide an accurate and convenient method for field icing measurement. In addition, by analyzing the characteristics of the tension and tilt of the insulator string at the iced tangent tower, a new mechanical calculation model considering the ice and wind loads was established. One-month field observations and experiments were conducted in XMNIS, and it is shown that the calculation results have good agreement with experiment results, which suggests that the model can be used for ice thickness calculation and online monitoring on transmission lines.

About this research paper

What this paper is about

Transmission-line icing presents a serious threat to the safe operation of power systems. Therefore, the icing condition of overhead transmission lines must be accurately calculated for online monitoring and prewarning systems. Based on the icing data obtained at Xuefeng Mountain Natural Icing Stations (XMNIS), the cross-sectional shape of glaze icing on conductors was studied, and the correction coefficient of the actual nonuniform ice was proposed to provide an accurate and convenient method for field icing measurement. In addition, by analyzing the characteristics of the tension and tilt of the insulator string at the iced tangent tower, a new mechanical calculation model considering the ice and wind loads was established. One-month field observations and experiments were conducted in XMNIS, and it is shown that the calculation results have good agreement with experiment results, which suggests that the model can be used for ice thickness calculation and online monitoring on transmission lines.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Transmission-line icing presents a serious threat to the safe operation of power systems. Therefore, the icing condition of overhead transmission lines must be accurately calculated for online monitoring and prewarning systems. Based on the icing data obtained at Xuefeng Mountain Natural Icing Stations (XMNIS), the cross-sectional shape of glaze icing on conductors was studied, and the correction coefficient of the actual nonuniform ice was proposed to provide an accurate and convenient method for field icing measurement. In addition, by analyzing the characteristics of the tension and tilt of the insulator string at the iced tangent tower, a new mechanical calculation model considering the ice and wind loads was established. One-month field observations and experiments were conducted in XMNIS, and it is shown that the calculation results have good agreement with experiment results, which suggests that the model can be used for ice thickness calculation and online monitoring on transmission lines.

Key concepts: Icing, Electric power transmission, Insulator (electricity), Overhead line, Transmission line, Electrical conductor, Overhead (engineering), Transmission tower

Related papers

Back to paper searchBrowse research topicsOriginal source
Predictive Model for Equivalent Ice Thickness Load on Overhead Transmission Lines Based on Measured Insulator String Deviations — Research Paper | ScholarLens