1998Journal of Speech Language and Hearing ResearchRequires access

Transient-Evoked Otoacoustic Emissions as a Measure of Noise-Induced Threshold Shift

Lynne Marshall, Laurie M. Heller

Open publisher page 36 citations

Abstract

Otoacoustic emissions and behavioral hearing thresholds were measured before and after exposure to a 10-min, 105-dB SPL, half-octave band of noise centered at 1.414 kHz. Along a single recovery function, transient-evoked otoacoustic-emission (TEOAE) measurements made with 74-dB pSPL nonlinear click ensembles were alternated with a Bekesy threshold-tracking procedure. Each of the 14 participants with normal hearing underwent 2 hour-long temporary-threshold shift (TTS) sessions as well as 2 pretest sessions and a posttest session. The Bekesy test frequency was fixed at 2.0 kHz, whereas emissions were analyzed in half-octave bandwidths with center frequencies ranging from 0.707 to 5.656 kHz. Results showed that (a) the maximum temporary emission shifts (TES) were half to 1 octave above the exposure frequency; (b) the 4.7-dB average temporary emission shift magnitude at approximately 2 min postexposure was less than half of the 11.7-dB average TTS; (c) the average recovery times for emissions and hearing thresholds were similar (188 vs. 186 min); and (d) the average TTS magnitude along the recovery function was predictable from TES magnitude. It is concluded that both TEOAEs and Bekesy thresholds reveal the same aspects of postexposure inner-ear changes.

About this research paper

What this paper is about

Otoacoustic emissions and behavioral hearing thresholds were measured before and after exposure to a 10-min, 105-dB SPL, half-octave band of noise centered at 1.414 kHz. Along a single recovery function, transient-evoked otoacoustic-emission (TEOAE) measurements made with 74-dB pSPL nonlinear click ensembles were alternated with a Bekesy threshold-tracking procedure. Each of the 14 participants with normal hearing underwent 2 hour-long temporary-threshold shift (TTS) sessions as well as 2 pretest sessions and a posttest session. The Bekesy test frequency was fixed at 2.0 kHz, whereas emissions were analyzed in half-octave bandwidths with center frequencies ranging from 0.707 to 5.656 kHz. Results showed that (a) the maximum temporary emission shifts (TES) were half to 1 octave above the exposure frequency; (b) the 4.7-dB average temporary emission shift magnitude at approximately 2 min postexposure was less than half of the 11.7-dB average TTS; (c) the average recovery times for emissions and hearing thresholds were similar (188 vs. 186 min); and (d) the average TTS magnitude along the recovery function was predictable from TES magnitude. It is concluded that both TEOAEs and Bekesy thresholds reveal the same aspects of postexposure inner-ear changes.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Otoacoustic emissions and behavioral hearing thresholds were measured before and after exposure to a 10-min, 105-dB SPL, half-octave band of noise centered at 1.414 kHz. Along a single recovery function, transient-evoked otoacoustic-emission (TEOAE) measurements made with 74-dB pSPL nonlinear click ensembles were alternated with a Bekesy threshold-tracking procedure. Each of the 14 participants with normal hearing underwent 2 hour-long temporary-threshold shift (TTS) sessions as well as 2 pretest sessions and a posttest session. The Bekesy test frequency was fixed at 2.0 kHz, whereas emissions were analyzed in half-octave bandwidths with center frequencies ranging from 0.707 to 5.656 kHz. Results showed that (a) the maximum temporary emission shifts (TES) were half to 1 octave above the exposure frequency; (b) the 4.7-dB average temporary emission shift magnitude at approximately 2 min postexposure was less than half of the 11.7-dB average TTS; (c) the average recovery times for emissions and hearing thresholds were similar (188 vs. 186 min); and (d) the average TTS magnitude along the recovery function was predictable from TES magnitude. It is concluded that both TEOAEs and Bekesy thresholds reveal the same aspects of postexposure inner-ear changes.

Key concepts: Auditory fatigue, Otoacoustic emission, Octave (electronics), Audiology, Octave band, Noise (video), Acoustics, Hearing loss

Related papers

Back to paper searchBrowse research topicsOriginal source
Transient-Evoked Otoacoustic Emissions as a Measure of Noise-Induced Threshold Shift — Research Paper | ScholarLens