Ground-reference calibration of Landsat-7 ETM+
Kurtis J. Thome, John H. LaMarr, Stuart F. Biggar, Aseneth S. Lopez
Abstract
Kurtis J. Thome, John H. LaMarr, Stuart F. Biggar, Aseneth S. Lopez
Abstract
Ground-reference techniques for the Enhanced Thematic Mapper Plus (ETM+) on Landsat 7 are described. The techniques are similar to those used for many years for Landsat-5 Thematic Mapper (TM). Recent results with the Landsat-5 TM are presented, including comparisons with hyperspectral, airborne imaging data. These results show that the Landsat sensor has remained stable within the 5% uncertainty of the ground- reference methods for the last five years. The airborne imagery is also used to show uncertainties due to registration errors, spectral differences, and spatial resolution differences in cross-comparison techniques planned for Earth Observing System sensors. In addition to the use of the traditional methods and test sites, a smaller test site local to the University of Arizona area is being evaluated for use with ETM+. This site, while not as bright, spatially- uniform and large as typical sites, allows more frequent calibrations and hopefully a better understanding of the calibration as a function of time. The selection of the test site, its properties, and example results of calibration of Landsat-5 TM are presented.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Ground-reference techniques for the Enhanced Thematic Mapper Plus (ETM+) on Landsat 7 are described. The techniques are similar to those used for many years for Landsat-5 Thematic Mapper (TM). Recent results with the Landsat-5 TM are presented, including comparisons with hyperspectral, airborne imaging data. These results show that the Landsat sensor has remained stable within the 5% uncertainty of the ground- reference methods for the last five years. The airborne imagery is also used to show uncertainties due to registration errors, spectral differences, and spatial resolution differences in cross-comparison techniques planned for Earth Observing System sensors. In addition to the use of the traditional methods and test sites, a smaller test site local to the University of Arizona area is being evaluated for use with ETM+. This site, while not as bright, spatially- uniform and large as typical sites, allows more frequent calibrations and hopefully a better understanding of the calibration as a function of time. The selection of the test site, its properties, and example results of calibration of Landsat-5 TM are presented.
Key concepts: Thematic Mapper, Remote sensing, Hyperspectral imaging, Calibration, Test site, Thematic map, Environmental science, Geology