2003•Journal of Orthopaedic and Sports Physical TherapyRequires access

Posterior-Anterior Glide of the Femoral Head in the Acetabulum: A Cadaver Study

Linn Harding, Mary Frances Barbe, Katherine F Shepard, Amy Marks, Raymond Ajai, Jennifer Lardiere, Heather Sweringa

Open publisher page 27 citations

Abstract

STUDY DESIGN: Descriptive study employing cadaver dissection and measurement of posterior-anterior (PA) glide of the femoral head in the acetabulum. OBJECTIVE: To quantify PA glide of the femoral head in the acetabulum in a cadaveric sample. BACKGROUND: Posterior-anterior glide of the femoral head within the acetabulum is a joint mobilization procedure described in orthopaedic physical therapy texts, yet there is no published evidence that the joint structures of the hip allow such movement. This study attempted to quantify PA glide of the femoral head in the hip joints of embalmed cadavers. METHODS: Twelve hips, 3 male and 9 female, from 8 embalmed cadavers were employed in this study. Hips were dissected to the level of the joint capsule and a metal rod inserted through the femoral neck served as a mobilizing handle. A load cell was installed into this handle so that mobilizing forces could be monitored. A dial gauge, which recorded displacement of the femoral head, was mounted to the pelvis via bone pins and an external fixator. RESULTS: Using mobilizing forces of 89, 178, 267, and 356 N, mean femoral head displacements of 0.57, 0.93, 1.20, and 1.52 mm were recorded. Within the 89-N trials, PA displacement ranged from a minimum of 0.04 mm to a maximum of 1.54 mm. Within the 356-N trials, PA displacement of the femoral head ranged from a minimum of 0.25 mm to a maximum of 2.90 mm. CONCLUSION: In an embalmed cadaveric model, measurable PA glide of the femoral head within the acetabulum does exist and it is highly variable between individuals.

About this research paper

What this paper is about

STUDY DESIGN: Descriptive study employing cadaver dissection and measurement of posterior-anterior (PA) glide of the femoral head in the acetabulum. OBJECTIVE: To quantify PA glide of the femoral head in the acetabulum in a cadaveric sample. BACKGROUND: Posterior-anterior glide of the femoral head within the acetabulum is a joint mobilization procedure described in orthopaedic physical therapy texts, yet there is no published evidence that the joint structures of the hip allow such movement. This study attempted to quantify PA glide of the femoral head in the hip joints of embalmed cadavers. METHODS: Twelve hips, 3 male and 9 female, from 8 embalmed cadavers were employed in this study. Hips were dissected to the level of the joint capsule and a metal rod inserted through the femoral neck served as a mobilizing handle. A load cell was installed into this handle so that mobilizing forces could be monitored. A dial gauge, which recorded displacement of the femoral head, was mounted to the pelvis via bone pins and an external fixator. RESULTS: Using mobilizing forces of 89, 178, 267, and 356 N, mean femoral head displacements of 0.57, 0.93, 1.20, and 1.52 mm were recorded. Within the 89-N trials, PA displacement ranged from a minimum of 0.04 mm to a maximum of 1.54 mm. Within the 356-N trials, PA displacement of the femoral head ranged from a minimum of 0.25 mm to a maximum of 2.90 mm. CONCLUSION: In an embalmed cadaveric model, measurable PA glide of the femoral head within the acetabulum does exist and it is highly variable between individuals.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

STUDY DESIGN: Descriptive study employing cadaver dissection and measurement of posterior-anterior (PA) glide of the femoral head in the acetabulum. OBJECTIVE: To quantify PA glide of the femoral head in the acetabulum in a cadaveric sample. BACKGROUND: Posterior-anterior glide of the femoral head within the acetabulum is a joint mobilization procedure described in orthopaedic physical therapy texts, yet there is no published evidence that the joint structures of the hip allow such movement. This study attempted to quantify PA glide of the femoral head in the hip joints of embalmed cadavers. METHODS: Twelve hips, 3 male and 9 female, from 8 embalmed cadavers were employed in this study. Hips were dissected to the level of the joint capsule and a metal rod inserted through the femoral neck served as a mobilizing handle. A load cell was installed into this handle so that mobilizing forces could be monitored. A dial gauge, which recorded displacement of the femoral head, was mounted to the pelvis via bone pins and an external fixator. RESULTS: Using mobilizing forces of 89, 178, 267, and 356 N, mean femoral head displacements of 0.57, 0.93, 1.20, and 1.52 mm were recorded. Within the 89-N trials, PA displacement ranged from a minimum of 0.04 mm to a maximum of 1.54 mm. Within the 356-N trials, PA displacement of the femoral head ranged from a minimum of 0.25 mm to a maximum of 2.90 mm. CONCLUSION: In an embalmed cadaveric model, measurable PA glide of the femoral head within the acetabulum does exist and it is highly variable between individuals.

Key concepts: Medicine, Acetabulum, Cadaver, Femoral head, Head (geology), Anatomy, Orthodontics, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Posterior-Anterior Glide of the Femoral Head in the Acetabulum: A Cadaver Study — Research Paper | ScholarLens