1998American Journal of RoentgenologyRequires access

Compliance with recommended follow-up after percutaneous breast core biopsy.

Karyn A. Goodman, Robyn L. Birdwell, Debra M. Ikeda

Open publisher page 56 citations

Abstract

OBJECTIVE: The purpose of this study was to use information from an established patient tracking system to evaluate patient outcome and assess patient compliance with recommended follow-up after percutaneous breast core biopsy. MATERIALS AND METHODS: All breast core biopsies performed from January 1994 through February 14, 1996, that used stereotaxic or sonographic guidance were reviewed. Clinical, imaging, and pathologic findings were correlated with patient outcomes established by recommended surgical and nonsurgical follow-up. RESULTS: Of 160 core biopsies in 153 women, 30 biopsies were performed on the basis of clinical complaints. One hundred thirty lesions were detected by mammography or sonography or both. Of the 70 lesions recommended for surgical excision, 52 (74%) had documented surgical outcomes. Mammographic surveillance was recommended for 90 lesions, of which 10 (11%) had resolved at the time of this study, 49 (54%) were on track toward 3-year lesion stability, 21 (23%) were being followed up elsewhere, four (4%) were lost to physicians, and six (7%) were lost to follow-up for other reasons. CONCLUSION: Known compliance with follow-up recommendations among these 153 patients who underwent breast core biopsy was higher for patients receiving surgical recommendation (74%) than for patients receiving imaging surveillance recommendation (54%). Problems tracking patients were caused both by loss of patients to follow-up and by incomplete reporting from referring physicians.

About this research paper

What this paper is about

OBJECTIVE: The purpose of this study was to use information from an established patient tracking system to evaluate patient outcome and assess patient compliance with recommended follow-up after percutaneous breast core biopsy. MATERIALS AND METHODS: All breast core biopsies performed from January 1994 through February 14, 1996, that used stereotaxic or sonographic guidance were reviewed. Clinical, imaging, and pathologic findings were correlated with patient outcomes established by recommended surgical and nonsurgical follow-up. RESULTS: Of 160 core biopsies in 153 women, 30 biopsies were performed on the basis of clinical complaints. One hundred thirty lesions were detected by mammography or sonography or both. Of the 70 lesions recommended for surgical excision, 52 (74%) had documented surgical outcomes. Mammographic surveillance was recommended for 90 lesions, of which 10 (11%) had resolved at the time of this study, 49 (54%) were on track toward 3-year lesion stability, 21 (23%) were being followed up elsewhere, four (4%) were lost to physicians, and six (7%) were lost to follow-up for other reasons. CONCLUSION: Known compliance with follow-up recommendations among these 153 patients who underwent breast core biopsy was higher for patients receiving surgical recommendation (74%) than for patients receiving imaging surveillance recommendation (54%). Problems tracking patients were caused both by loss of patients to follow-up and by incomplete reporting from referring physicians.

Why it matters

OpenAlex reports 56 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: The purpose of this study was to use information from an established patient tracking system to evaluate patient outcome and assess patient compliance with recommended follow-up after percutaneous breast core biopsy. MATERIALS AND METHODS: All breast core biopsies performed from January 1994 through February 14, 1996, that used stereotaxic or sonographic guidance were reviewed. Clinical, imaging, and pathologic findings were correlated with patient outcomes established by recommended surgical and nonsurgical follow-up. RESULTS: Of 160 core biopsies in 153 women, 30 biopsies were performed on the basis of clinical complaints. One hundred thirty lesions were detected by mammography or sonography or both. Of the 70 lesions recommended for surgical excision, 52 (74%) had documented surgical outcomes. Mammographic surveillance was recommended for 90 lesions, of which 10 (11%) had resolved at the time of this study, 49 (54%) were on track toward 3-year lesion stability, 21 (23%) were being followed up elsewhere, four (4%) were lost to physicians, and six (7%) were lost to follow-up for other reasons. CONCLUSION: Known compliance with follow-up recommendations among these 153 patients who underwent breast core biopsy was higher for patients receiving surgical recommendation (74%) than for patients receiving imaging surveillance recommendation (54%). Problems tracking patients were caused both by loss of patients to follow-up and by incomplete reporting from referring physicians.

Key concepts: Medicine, Percutaneous, Core biopsy, Biopsy, Compliance (psychology), Percutaneous biopsy, Radiology, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Compliance with recommended follow-up after percutaneous breast core biopsy. — Research Paper | ScholarLens