SU‐GG‐I‐11: Dose and Image Quality Evaluation of a Mobile CT Scanner for Head and Neck Imaging

Eric L. Gingold, Jaydev Kardam Dave

Open publisher page 0 citations

Abstract

Purpose: To evaluate the radiation dose delivered to patients and personnel by a mobile x‐ray CT scanner designed for bedside imaging of the head and neck, and to examine image quality under clinical conditions. Method and Materials: Computed Tomography Dose Index (CTDI) was measured using a 100 mm pencil ionization chamber and 16 cm diameter acrylic phantom over a range of acquisition parameters on a mobile CT scanner (Neurologica Ceretom, Danvers, MA). Scatter radiation was measured using the same phantom. Image quality was evaluated using the manufacturer's QA phantom and the common CATPHAN phantom. Results: At 120 kVp, CTDI‐100 measured 44.8, 83.5, and 122 mGy at 7 mA and 2, 4, and 6 seconds per rotation, respectively. At 140 kVp, commonly used for head scanning, the CTDI‐100 measured 65.3, 126.8, and 176.3 mGy at 7 mA and 2, 4, and 6 seconds per rotation, respectively. All measured doses were within 10% of the CTDI values indicated to the operator on the scanner's console. Using protective lead curtains provided with the scanner, scatter radiation was well within ALARA standards. CATPHAN images demonstrated acceptable alignment, slice width and incrementation accuracy, geometric accuracy, low contrast resolution, high contrast spatial resolution, image uniformity and CT number linearity at clinical techniques. Conclusion: When operated in “low dose” (2 seconds/rotation) mode, the radiation dose delivered by the mobile CT scanner is below or comparable to the ACR's diagnostic Reference Value (RV) for head CT dose. The “standard” (4 seconds/rotation) and “high‐quality” (6 seconds/rotation) modes deliver more radiation, with a corresponding increase in image quality. Assessment using an industry‐standard phantom produced acceptable image quality performance under clinical conditions. With proper precautions, the scanner can be safely used in most intensive care environments without additional shielding, with minimal occupational exposure.

About this research paper

What this paper is about

Purpose: To evaluate the radiation dose delivered to patients and personnel by a mobile x‐ray CT scanner designed for bedside imaging of the head and neck, and to examine image quality under clinical conditions. Method and Materials: Computed Tomography Dose Index (CTDI) was measured using a 100 mm pencil ionization chamber and 16 cm diameter acrylic phantom over a range of acquisition parameters on a mobile CT scanner (Neurologica Ceretom, Danvers, MA). Scatter radiation was measured using the same phantom. Image quality was evaluated using the manufacturer's QA phantom and the common CATPHAN phantom. Results: At 120 kVp, CTDI‐100 measured 44.8, 83.5, and 122 mGy at 7 mA and 2, 4, and 6 seconds per rotation, respectively. At 140 kVp, commonly used for head scanning, the CTDI‐100 measured 65.3, 126.8, and 176.3 mGy at 7 mA and 2, 4, and 6 seconds per rotation, respectively. All measured doses were within 10% of the CTDI values indicated to the operator on the scanner's console. Using protective lead curtains provided with the scanner, scatter radiation was well within ALARA standards. CATPHAN images demonstrated acceptable alignment, slice width and incrementation accuracy, geometric accuracy, low contrast resolution, high contrast spatial resolution, image uniformity and CT number linearity at clinical techniques. Conclusion: When operated in “low dose” (2 seconds/rotation) mode, the radiation dose delivered by the mobile CT scanner is below or comparable to the ACR's diagnostic Reference Value (RV) for head CT dose. The “standard” (4 seconds/rotation) and “high‐quality” (6 seconds/rotation) modes deliver more radiation, with a corresponding increase in image quality. Assessment using an industry‐standard phantom produced acceptable image quality performance under clinical conditions. With proper precautions, the scanner can be safely used in most intensive care environments without additional shielding, with minimal occupational exposure.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: To evaluate the radiation dose delivered to patients and personnel by a mobile x‐ray CT scanner designed for bedside imaging of the head and neck, and to examine image quality under clinical conditions. Method and Materials: Computed Tomography Dose Index (CTDI) was measured using a 100 mm pencil ionization chamber and 16 cm diameter acrylic phantom over a range of acquisition parameters on a mobile CT scanner (Neurologica Ceretom, Danvers, MA). Scatter radiation was measured using the same phantom. Image quality was evaluated using the manufacturer's QA phantom and the common CATPHAN phantom. Results: At 120 kVp, CTDI‐100 measured 44.8, 83.5, and 122 mGy at 7 mA and 2, 4, and 6 seconds per rotation, respectively. At 140 kVp, commonly used for head scanning, the CTDI‐100 measured 65.3, 126.8, and 176.3 mGy at 7 mA and 2, 4, and 6 seconds per rotation, respectively. All measured doses were within 10% of the CTDI values indicated to the operator on the scanner's console. Using protective lead curtains provided with the scanner, scatter radiation was well within ALARA standards. CATPHAN images demonstrated acceptable alignment, slice width and incrementation accuracy, geometric accuracy, low contrast resolution, high contrast spatial resolution, image uniformity and CT number linearity at clinical techniques. Conclusion: When operated in “low dose” (2 seconds/rotation) mode, the radiation dose delivered by the mobile CT scanner is below or comparable to the ACR's diagnostic Reference Value (RV) for head CT dose. The “standard” (4 seconds/rotation) and “high‐quality” (6 seconds/rotation) modes deliver more radiation, with a corresponding increase in image quality. Assessment using an industry‐standard phantom produced acceptable image quality performance under clinical conditions. With proper precautions, the scanner can be safely used in most intensive care environments without additional shielding, with minimal occupational exposure.

Key concepts: Imaging phantom, Scanner, Image quality, Ionization chamber, Nuclear medicine, Dosimetry, Image resolution, Medicine