1980Physical review. B, Condensed matterRequires access

Extended x-ray absorption fine-structure determinations of coordination numbers: Limitations

P. Eisenberger, B. Lengeler

Open publisher page 96 citations

Abstract

Comparisons are made between measured extended x-ray absorption fine-structure (EXAFS) amplitudes for nearest- and more-distant-neighbor coordination shells in a wide variety of known compounds at both room temperature and 77 K. The comparisons reveal a significant sensitivity of the amplitudes to the chemical environment and non-Gaussian disorder. The observed changes can cause significant errors in the empirical determinations of coordination numbers. The absence of the possibility of a quantitative theoretical calculation of the EXAFS amplitude leads to the conclusion that coordination numbers can be determined most accurately by the use of a chemically and structurally similar model measured at low temperature.

About this research paper

What this paper is about

Comparisons are made between measured extended x-ray absorption fine-structure (EXAFS) amplitudes for nearest- and more-distant-neighbor coordination shells in a wide variety of known compounds at both room temperature and 77 K. The comparisons reveal a significant sensitivity of the amplitudes to the chemical environment and non-Gaussian disorder. The observed changes can cause significant errors in the empirical determinations of coordination numbers. The absence of the possibility of a quantitative theoretical calculation of the EXAFS amplitude leads to the conclusion that coordination numbers can be determined most accurately by the use of a chemically and structurally similar model measured at low temperature.

Why it matters

OpenAlex reports 96 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Comparisons are made between measured extended x-ray absorption fine-structure (EXAFS) amplitudes for nearest- and more-distant-neighbor coordination shells in a wide variety of known compounds at both room temperature and 77 K. The comparisons reveal a significant sensitivity of the amplitudes to the chemical environment and non-Gaussian disorder. The observed changes can cause significant errors in the empirical determinations of coordination numbers. The absence of the possibility of a quantitative theoretical calculation of the EXAFS amplitude leads to the conclusion that coordination numbers can be determined most accurately by the use of a chemically and structurally similar model measured at low temperature.

Key concepts: Extended X-ray absorption fine structure, Coordination number, Amplitude, Absorption (acoustics), Gaussian, X-ray absorption fine structure, Materials science, X-ray

Related papers

Back to paper searchBrowse research topicsOriginal source
Extended x-ray absorption fine-structure determinations of coordination numbers: Limitations — Research Paper | ScholarLens