2014•Unpublished venueRequires access

CMOS Instrumentation amplifier design with 180nM technology

Gaytri Gupta, Malay Ranjan Tripathy

Open publisher page 7 citations

Abstract

This paper description of the design technique of Instrumentation Amplifier used in biomedicai appliances. This Instrumentation amplifier is designed with the combination of Operational Tranconductance amplifier (OTA). We have used the Operational Tranconductance amplifier due to its high input impedance, low output impedance, low DC offset, low noise, high common mode rejection ratio (CMRR) and high power supply rejection ratio (PSRR). The circuit has been designed with the Cadence Virtusoo Software with 180 nM technology. The main features of this OTA are 20.13 dB open loop gain with a 0.23 KHz bandwidth, 124 dB CMRR, 65 dB PSRR and offset voltage is 0.3mV DC. The integrated CMOS amplifier operates to IV power supply. The design and Simulation of this IA is completed using CADENCE Spectre with UMC 0.18 μm technology. The power dissipation of this instrumentation amplifier is 0.50 mW.

About this research paper

What this paper is about

This paper description of the design technique of Instrumentation Amplifier used in biomedicai appliances. This Instrumentation amplifier is designed with the combination of Operational Tranconductance amplifier (OTA). We have used the Operational Tranconductance amplifier due to its high input impedance, low output impedance, low DC offset, low noise, high common mode rejection ratio (CMRR) and high power supply rejection ratio (PSRR). The circuit has been designed with the Cadence Virtusoo Software with 180 nM technology. The main features of this OTA are 20.13 dB open loop gain with a 0.23 KHz bandwidth, 124 dB CMRR, 65 dB PSRR and offset voltage is 0.3mV DC. The integrated CMOS amplifier operates to IV power supply. The design and Simulation of this IA is completed using CADENCE Spectre with UMC 0.18 μm technology. The power dissipation of this instrumentation amplifier is 0.50 mW.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper description of the design technique of Instrumentation Amplifier used in biomedicai appliances. This Instrumentation amplifier is designed with the combination of Operational Tranconductance amplifier (OTA). We have used the Operational Tranconductance amplifier due to its high input impedance, low output impedance, low DC offset, low noise, high common mode rejection ratio (CMRR) and high power supply rejection ratio (PSRR). The circuit has been designed with the Cadence Virtusoo Software with 180 nM technology. The main features of this OTA are 20.13 dB open loop gain with a 0.23 KHz bandwidth, 124 dB CMRR, 65 dB PSRR and offset voltage is 0.3mV DC. The integrated CMOS amplifier operates to IV power supply. The design and Simulation of this IA is completed using CADENCE Spectre with UMC 0.18 μm technology. The power dissipation of this instrumentation amplifier is 0.50 mW.

Key concepts: Power supply rejection ratio, Instrumentation amplifier, Input offset voltage, Electrical engineering, CMOS, Operational amplifier, Direct-coupled amplifier, Operational transconductance amplifier

Related papers

Back to paper searchBrowse research topicsOriginal source
CMOS Instrumentation amplifier design with 180nM technology — Research Paper | ScholarLens